- 5 -

 

 

 

Table 1 

 

TYPE

 

 

OKHE 

ONE/E 30

 

OKHE 

ONE/E 50 

 

OKHE 

ONE/E 80 

 

OKHE 

ONE/E 100

 

OKHE 

ONE/E 120 

 

VOLUME

 

28 

41 

65 

80 

98 

MAX OPERATING 
OVERPRESSURE 
IN THE TANK

 

bar 

ELECTRICAL CONNECTION

 

 

1/N/PE ~ 230V/50Hz 

RECOMMENDED BREAKER

 

 

10 A 

16 A 

INPUT

 

1100 

2000 

EL. PROTECTION

 

 

IP 44 

MAX OPERATING 
TEMPERATURE OF HOT 
WATER (HW)

 

°C

 

80 

RECOMMENDED HOT 
WATER (HW) 
TEMPERATURE

 

°C

 

60 

HEIGHT OF THE HEATER

 

mm 

617 

845 

1112 

1327 

1552 

HEATER DIMENSION 
width x depth

 

mm 

523x318 

MAX WEIGHT OF THE 
HEATER WITHOUT WATER

 

kg 

22 

31 

46 

55 

62 

TIME OF EL. HEATING 

FROM 10°C TO 60°C 

 

hours 

1,5 

1,5 

2,5 

MIXED WATER V40 

39.37 

72.16 

88.77 

113.12 

118.16 

LOAD PROFILE 

 

ENERGY EFFICIENCY CLASS 

 

ENERGY EFFICIENCY

 

33 

38 

37 

37 

37 

ANNUAL CONSUMPTION 
OF ELECTRIC ENERGY

 

kWh 

561 

1353 

1378 

1405 

1403 

Содержание OKHE ONE/E 120

Страница 1: ...ER FOR VERTICAL MOUNTING Electric water heaters OKHE ONE E 30 OKHE ONE E 50 OKHE ONE E 80 OKHE ONE E100 OKHE ONE E 120 Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou te...

Страница 2: ...INSTALLATION 12 2 4 1 GENERAL INFORMATION FOR ELECTRICAL INSTALLATION 12 2 5 OPERATING ACTIVITY 13 2 6 FIRST COMMISSIONING 13 2 7 PUTTING OUT OF SERVICE DISCHARGE 14 2 8 INSPECTION MAINTENANCE CARE F...

Страница 3: ...le person or unless properly instructed by such responsible person The manufacturer reserves the right for engineering modification of the product The product is designed for permanent contact with dr...

Страница 4: ...MERS 1 2 1 HOT WATER CONSUMPTION Consumption of hot water in households depends on the number of people amount of sanitary equipment length diameter and insulation of piping in the flat or on individu...

Страница 5: ...ERATURE OF HOT WATER HW C 80 RECOMMENDED HOT WATER HW TEMPERATURE C 60 HEIGHT OF THE HEATER mm 617 845 1112 1327 1552 HEATER DIMENSION width x depth mm 523x318 MAX WEIGHT OF THE HEATER WITHOUT WATER k...

Страница 6: ...e flange lid and the safety fuses and the second flange lids are without thermowells An anode rod is mounted onto the M8 nut Electric wiring is placed underneath the plastic removable cover Descriptio...

Страница 7: ...E ONE E 30 OKHE ONE E 50 OKHE ONE E 80 OKHE ONE E 100 OKHE ONE E 120 A 617 845 1112 1327 1552 B 318 318 318 318 318 D 523 523 523 523 523 E 500 730 920 1135 1360 F 350 560 750 950 1150 H 110 110 190 1...

Страница 8: ...2 2 WALL MOUNTING Prior to the mounting check the bearing capacity of the wall and the material it is made of considering the weight of the heater filled with water Depending on the wall material choo...

Страница 9: ...energetic performance drop will always occur due to deteriorated stratification of water However neither lifecycle nor terms of warranty are changed thereby Our heaters are tested for operation in th...

Страница 10: ...peration of the check valve with a check valve and a relief valve Figure 6 The safety valve with a check valve is supplied with the heater It is necessary to check the safety valve each time before pu...

Страница 11: ...11 Table 3 Figure 6 Figure 7 SAFETY VALVE START UP PRESSURE MPa ALLOWABLE OPERATING OVERPRESSURE OF WATER HEATER MPa MAXIMUM PRESSURE IN COLD WATER PIPES MPa 0 6 0 6 up to 0 48...

Страница 12: ...ure 8 The electric installation may only be connected repaired and inspected only by a person authorized to perform that activity Professional connection must be confirmed on the warranty card or supp...

Страница 13: ...lake symbol to avoid freezing or turn off the power supply into the heater Setting the thermostat to the zero position does not mean the heater has been turned off In case of a power failure the displ...

Страница 14: ...supply piping through the discharge valve for safety valve combination and with simultaneous opening of all hot water valves of connected fittings water can be also drained through safety valve for t...

Страница 15: ...same as during the initial putting in operation Do not use any abrasive cleaning agents such as liquid sand chemicals acid alkaline or dye thinners such as cellulose thinner trichlor and the like to...

Страница 16: ...ration thermostat Water is not warm enough Light on Failure of one of the coils in the element 2x 1000 W Temperature of water is not corresponding with the temperature set on the control Defective the...

Страница 17: ...e used for any handling with the heater 3 1 1 TEMPERATURE SETTING Water temperature is set by turning the thermostat knob The desired symbol is adjusted against the fixed point on the control panel Fi...

Страница 18: ...ing adjustment and replacement of the regulation elements shall only be performed by an authorized service company The thermal fuse must not be turned off In case of thermostat defect the thermal fuse...

Страница 19: ...is F06020274 Take the water heater packaging to a waste disposal place determined by the municipality When the operation terminates disassemble and transport the discarded and unserviceable heater to...

Отзывы: