5
Specifications
EPQ DataNode Series User’s Guide
5-1
DataNode Specifications
5530 / 5520 / 5513 / 5510
Inputs
Voltage
#V channels
4
V range (RMS)
5-600
V accuracy
±0.2% reading, ±0.2% full scale
Sample rate
Max 384 samples/cycle (128 s/c + dual peak detectors for 5510T, 5513T, 5520T,
5530T), phase locked
Input type
(for 5530) Single Ended, DC coupled with 5531 V Pod
(for 5520 and 5536 V Pod) Differential, DC coupled
Input impedance
(for 5530) 2 Mohm to ground
(for 5520 and 5536 V Pod) 8 Mohm to ground
CMMR
-80 dB
Connection Type
(for 5510/5530) External Module w/screw terminals
(for 5520) Removable Screw Terminal Blocks
(for 5513) Plug-in connection
RMS Update
1/2 cycle steps
RMS Compression
on long duration RMS events, 3 stages
#Waveforms
0-7 Pre-, 16-Before Post-
Current
#I channels
4
I range (RMS) nominal
5A
I range peak
5x with 5532 pod, 20x with 5533
I accuracy
±0.2% reading, ±0.2% full scale
RMS Sample rate
Max 384 samples/cycle (128 s/c + dual peak detectors for 5510T, 5513T, 5520T,
5530T), synchronous with corresponding voltage channel
CMMR
-80 dB
Connection Type
(for 5510/5530) External Module w/ 3/8" Toroid, #12 AWG wire
(for 5520 and 5537 A Pod) Removable Screw Terminals, #10 Block
(for 5513) Plug-in connection
RMS Update
1/2 cycle steps
#Waveforms
0-7 Pre-, 16-Before Post-
Phase shift V&I
0 degrees
Voltage Transients
PLL Synchronization
Yes
Zero crossing
sample synchronization
Yes
V transient peak
± 50-1000Vpk
V transient min duration
1 µsec for less than -3db
Trigger techniques
Dual hi freq. peak detectors, waveshape, and instantaneous or crest peak
Update rate @60Hz
130 µsec
Current Transients
I transient
Yes
I transient peak
10-300% CT FS
I transient duration
1 µsec for less than -3db
Update rate @60Hz
130 µsec
Trigger techniques
Dual hi freq. peak detectors, instantaneous or crest peak