THE UNIT WON’T START UP...
SOLUTION:
• Check the circuit breaker in your electrical panel.
• Check the unit’s circuit fuse/breaker.
• Check the 24V circuit, as follows:
Try to establish electrical contact in a wall inlet with a metal object (for example, a coin).
• If the unit starts up, the suction hose is defective.
• If the unit doesn’t start up, check to see if the 24V wires are properly connected to the unit.
Try to establish an electrical contact between the two terminals of the 24V circuit on the unit with a metal
object (for example, a screwdriver).
• If the unit starts up, a 24V wire is either cut or disconnected from one of the wall inlets.
• If the unit won’t start up after these steps, the printed circuit is defective.
THE UNIT WON’T SHUT DOWN…
SOLUTION:
Check the 24V circuit as follows:
Disconnect one of the two wires on the unit’s 24V circuit.
• If the unit shuts down, the problem could be that two 24V wires are touching themselves somewhere or
that the wall inlet is defective.
• If the unit doesn’t shut down, the printed circuit is defective. Unplug the power cord.
If you wish to speak with a customer service representative, please contact your supplier/dealer.