7
6
Drainvac Automatik central systems are designed to vacuum both solids and liquids. The canister never
needs to be emptied manually since the wastewater is automatically evacuated through the building’s
drainpipe or can be redirected to a nearby floor drain.
Step 1
Unit is off.
Step 2
Start up: The dirt begins to be
vacuumed and water flows in.
Water comes into
contact with the
electrodes
The rubber
hand opens
The rubber hand
is closed
Step 3
Water flows in, reaching the
electrodes (approx. 10 minutes).
Step 4
The wastewater is evacuated
(approx. 20 seconds).
To see a video of the sequence, go to
https://www.youtube.com/watch?v=VEnUJxHEN4M
OPERATION SEQUENCE
The sensitivity of the electrodes can be modified by the printed circuit board.
See Annex for more information.
HOW THE SYSTEM WORKS
HOW THE SYSTEM WORKS