31
30
INSTALLING THE UNIT
-
STEP SEQUENCE -
Clamp
2) CONNECT THE DUST AND WATER INLETS
• Connect the building’s cold water supply to the unit’s water inlet.
Clamp
Practical plug
for maintenance
(When needed, use
a brush to clean the
inside of the tubes)
•
A backflow preventer may be required
in some municipalities.
It is installed at
the water input of the unit and prevents
a backflow from the unit in the main
pipeline of the residence.
• Connect the dust inlet (transparent
tubes) to the unit securing it with a clamp.
* N.B. The tubes have been pre-
assembled by pressure.
Do not use glue.
• Connect the suction hose to the unit’s
dust inlet, securing it with a clamp.
Backflow preventer
(Optional, sold separately)
Screw the metal
hose* with the
connector.
*Recommended
replacing the hose
every 10 years.
POSITIONING THE WATER INJECTORS
ON THE DUST INLET
Some units are equipped with two water injectors. In this case, it is important that they be positioned facing
each other so that the water covers a greater surface.
3) CONNECT THE WATER OUTLET
• Connect the unit’s water outlet to the water hoses linked to the water injectors.
INSTALLING THE UNIT
-
STEP SEQUENCE -