1. Install the Control
FRONT
CASE
7000-100-031-V1
MOUNTING
HOLES (4)
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
TIE WRAP
POINT (2)
ILP5
SPACER
DETAIL A
BACK
CASE
POWER
RECEPTACLE
CASE
TAMPER
INSTALL
SCREW
IN CASE
TAMPER
TAMPER
SWITCH
EDGE
CONNECTOR
BATTERY WIRE
ROUTING CLIPS (3)
MOUNTING
HOOKS
(HINGES)
BATTERY
CABLE CHANNEL
LOCKING TABS
TIE WRAP
POINTS (2)
TERMINAL
STRIP
EDGE
CONNECTOR
COMMUNICATION
MODULE
RECEPTACLE
2. Make Wiring Connections
7000-100-040-V1
2K
OHM
EOLR
HARD
WIRED
ZONE
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM
EGND
EARTH
GROUND
HWZ1
TRIG
GND
GND
+9VDC
STANDARD CAPACITY
BATTERY CONNECTORS
SUPER HIGH CAPACITY
BATTERY CONNECTOR
ZONES
POWER
EDGE CONNECTOR
(L5200-ZWAVE-EU)
EDGE CONNECTOR
(L5100-WIFI-ME)
TRIGGER OUTPUT (NEG)
(3ma)
OBSERVE POLARITY WHEN CONNECTING
THE POWER SUPPLY TO THE TERMINAL STRIP.
NOTE
THE 300-04705V1 OR
300-04705V1-EUR IS
AVAILABLE FROM
HONEYWELL AND MUST
BE PROVIDED DURING
INSTALLATION
300-04705V1 OR
300-04705V1-EUR
POWER SUPPLY
9VDC, 2.5A
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
Note:
For the complete Summary of Connections, refer to the LYNX
Touch Series Installation and Setup Guide P/N 800-16082 or
higher.
3. Install the Communications Module
Ensure that SIM card and the connector board are securely
installed in the communications module before installing it in
the LYNX Touch.
4. Make Battery Connections
7000-100-029-V0
OR
RETAINER
SCREW
RETAINER
SCREW
BATTERY PACK
(P/N 300-03866/
LYNXRCHKIT-SHA)
BATTERY PACK
(P/N 300-03864-1/
LYNXRCHKIT-SC)
1. Release the front case from the rear case by depressing the two
locking tabs at the top of the unit with the blade of a medium size
screwdriver.
2. Separate the front and back case assemblies by rotating the front
case so that it is perpendicular to the rear case and unsnapping
(releasing) the two hooks (hinges) from the back case.
3. Feed the wiring through the appropriate openings in the back
case. Use tie wraps to secure the wiring to the built-in wire loops
as needed.
4. Mount the back case to a sturdy wall and secure with the provided
screws.
5. If required, install an additional mounting screw in the case
tamper (see Detail A).
6. Attach the front and back cases by connecting the hooks on the
front case to the attachments on back case. Once attached, the
hooks will support the front case and allow you to make the wiring
connections.
7. After all of the wiring connections have been made, snap the front
case and back case closed and ensure that the locking tabs
secure the case.
1. Make earth ground connections to EGND terminal.
2. Connect the sensors/contacts to the HWZ1 (+) and GND (-)
terminals.
3. If used, install the communications module Refer to the Install the
Communications Module section or to the Installation Guide for
the Communications Module.
4. Connect wires from the 300-04705V1, 300-04065V1 OR 300-
04063V1 (Canada) Power Supply to GND (-) and +9VDC (+)
terminals OR plug the Power Supply connector into the receptacle
on the LYNX Touch.
!
RF Exposure Warning
The antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 7.8 in (20 cm) from all
persons and not co-located or operated in conjunction with any
other transmitter except in accordance with FCC multi-transmitter
product procedures.
Important Note
If an external cellular radio antenna is used, the antenna must be
installed or replaced ONLY by a professional installer.
1. If you are installing the ILP5 module, use a wire cutter or knife to cut
the plastic tabs that secure the ILP5 spacer to the back case of the
LYNX Touch L7000. If you are installing a cellular communication
module, proceed to step 3.
2. Remove the ILP5 receptacle knockout from the left side of the
LYNX Touch back case
3 Install the Communications Module into the front case. Ensure that
the connector board is properly seated into the receptacle on the
control.
4 Secure the module with the three provided screws. If you are
installing the ILP5 module, proceed to step 5. If you are installing a
cellular communication module, proceed to step 8
5. Insert the ILP5 receptacle and spacer into the slot on the back
case.
6. Secure the communications cable to the tie wrap point on the ILP5
with the provided tie wrap.
7. Connect the Ethernet cable to the RJ45 receptacle.
8. Enable the module, configure alarm reporting and module
supervision and register the device. Refer to the “Communications
Diagnostics” section of the LYNX Touch L7000 Installation Guide
(P/N 800-16082 or higher).
1. Insert battery pack into back case.
2. Install battery retainer.
3. Install screw to secure the battery retainer.
4. Connect battery connector to receptacle on PC board.
5. After all wiring connections have been made, snap the front case
to the back case so it is held by the locking tabs.
6. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet.
Note:
Rechargeable batteries may take up to 48-hours to fully
charge. “Battery Low” message should clear within four hours,
or by entering Test Mode.
Battery
Part Number
Battery Standby
Time (Minimum)
Low Battery Notification
LYNXRCHKIT-SC
(300-03864-1)
4-hours
Approx. 1-hour before
battery depletion
LYNXRCHKIT-SHA
(300-03866)
24-hours
At least 1-hour before
battery depletion
Ê800-16088V1lŠ
800-16088V1 11/17 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2017 Honeywell International Inc.
www.honeywell.com/security
CONNECTOR
BOARD
ILP5
LYNX TOUCH
REMOVE
ILP5
SPACER
REMOVE
ILP5
KNOCKOUT
SIM CARD
7000-100-032-V2
ROTATED
180
ROTATED
180
CONNECTOR BOARD
CONNECTOR BOARD
TIE
WRAP
POINT
NOTE:
SIM CARD INSTALLED
IN 3GL/3GLC ONLY
ILP5
SPACER
TIE
WRAP
(1)
LYNX TOUCH
ALTERNATE INSTALLATION
RJ45
RECEPTACLE
RJ45 RECEPTACLE
ETHERNET CABLE
SCREW
(3)
TO ILP5
RECEPTACLE
CELLULAR
COMMUNICATION
MODULE
(3GL/3GLC SHOWN)