Programming Notes 

Entering Installer Programming mode 

1.  Power-up the control and allow it to “boot-up”. System 

Standby! is displayed on the touch screen. 

2.  When the “boot-up” is complete (approximately 1-2 minutes) 

“Ready to Arm” is displayed.  

3.  Select the “Security icon. 
4.  Select the “more”  tab on the first page of the Home Screen. 
5.  Select “Tools” button. 
6.  Enter the 4-digit Installer Code (4-1-1-2).  
7.  Select “Program” button. 
8.  The System Programming Screen will appear and the Home 

key will flash Green. 

Exiting Programming mode 

1.  Once programming is completed, at the System Programming 

screen, select the “

” button. 

2.  Select the “Yes” when the system prompts “Allow Installer to 

Re-Enter Programming?”. 

3.  Select the “Home” key to return to the Home Screen. 

Entering Master User Programming mode 

1. Power-up the control and select the “more” tab on the second 

page of the Security Screen. 

2. Select “Tools” icon. 
3. Enter the 4-digit Master User Code (1-2-3-4).  
4. The Master User Programming Screen will appear and the 

Home key will flash Green, 

5. Select the applicable programming function from the Master 

User screen. 

Exiting Programming mode 

1.  Once programming is completed, select the “

” button to 

return to the Master User Programming Screen. OR  

2.  Depress the “Home” key. 
3.  The system returns to the Home Screen. 

5.  Program the Control  

Change the Installer Code 

The factory default Installer Code for the LYNX Touch L7000 Series 
Control is set to 4-1-1-2. To change this code, you must enter 
Programming mode. 
1.  Select “Program” button. 
2.  Select “Installer Code” button. The current Installer Code is 

displayed. 

3.  Select the “Clear” button then enter a new 4-digit Installer Code. 
4.  Select “Done” button 

Program Date  

Note:

  If you are installing a Cellular, L5100-WiFi or ILP5 

Communication Module, the time and date will be programmed 
and updated automatically via Central Station. You must still 
program the correct Time Zone

 

To change this code, you must enter Programming mode. 
1.  Select “Program” button. 
2.  Select “Date Time” button. 
3.  Enter the date, time and time zone as required. 
4.  Select “Save” button. 

Program Defaults 

LYNX Touch is pre-programmed at the factory with a built-in set of 
default values. Refer to the Programming Default Tables section of 
the LYNX Touch Series Installation and Setup Guide (P/N 800-16082 
or higher) to view the Default Tables. To select factory defaults from 
a set of four tables, you must enter Programming mode. 
1.  Select “Program” button. 
2.  Select “Default Config.” button. 
3.  Select the desired Default Configuration. 
4.  Select “Yes” when the confirmation screen appears. 

 

6.  Add Wireless Sensors 

Add a Sensor 

To add, edit or delete Wireless Sensors you must enter Programming 
Mode. 
1.  Select “Zones” button. 
2.  Select “’Add new” button. 
3.  Select the applicable Zone button. 
4.  Select “Serial Number” button 
5.  Enter Serial Number on the displayed keypad OR 

Enroll via RF 

Learning.

 To enroll the transmitter, three (open/close) 

transmissions of the device will be required.  

6.  If desired, program the following options: 

Loop Number 
Zone Description 1 and 2 
Device Type 
Response Type 
Alarm Report 
Chime 
Supervision 
Arm Night (if applicable) 

7. Select “Save”. 

Edit Wireless Sensor/Zone information 

1.  Select “Zones” button. 
2.  Select the Zone you wish to edit and then select the “Edit” button. 
3.  Edit the applicable zone programming fields as required. 
4.  Select “Save”. 

Delete a Wireless Sensor 

1.  Select “Zones” button. 
2.  Select the Zone you wish to delete then select the “Delete” button. 
3.  Select the “Yes” button when the confirmation screen appears. 

7.  Add Wireless Keys 

To add, edit or delete a Wireless Key you must enter Programming 
Mode. 

Add a Wireless Key 

1.  Select “Keys” button. 
2.  Select ’Add New” button. 
3.  Select the “Key Type” button and scroll through the available key 

types. 

4.  Select “Serial Number” Button 
5.  Enter Serial Number or 

Enroll via RF Learning.

 To enroll the 

transmitter, three (open/close) transmissions of the device will be 
required.  

6.  Select the “User” button and then select the User that will be 

associated with the key that is being enrolled.  

Note:

   A valid User Code must be associated with the User assigned 

to the key. 

7.  If desired, program the following options: 

Zone 
Button Key * - Zn ** 

8.  Select “Save”. 

*  Button number is determined by the type of key being enrolled. 
** Zn No. based on the type of key being enrolled. 

Edit Wireless Key information 

1.  Select “Keys” button. 
2.  Select the Key you wish to edit and then select the “Edit” button. 
3.  Edit the applicable fields as required  
4.  Select “Save”. 

Delete a Wireless Key 

1.  Select “Keys” button. 
2.  Select the Key you wish to delete then select the “Delete” button. 
3.  Select the “Yes” button when the confirmation screen appears.

 

 

8.  Add Central Station Accounts 

To add Central Station Account information, you must enter 
Programming Mode. 

Add First or Second Central Station Information 

1.  Select the “Reporter” button. 
2.  Select the “Primary CS Info” or “Secondary CS Info” button. 
3.  Program the following fields as applicable: 

Phone Type 
Phone Number 
Communicator Type 
Account Number 
Dynamic Priority 
Dynamic Delay 
Report All 
Report Alarms 
Report Troubles 
Report Open/Close 
Report Tests 

4.  Select the “Save” button when programming is complete. 

 

!

 

All  four  digits  of  the  Central  Station  Account  numbers 
must be entered. For ten-digit format, all ten digits must be 
entered.  Refer  to  the  LYNX  Touch  Series  Installation  and 
Setup  Guide  for  additional  information  regarding  these 
programming options. 

 

9. Register the Communications Module 

The Communications Module can be registered either via the 
AlarmNet Direct Website, by Phone or through the LYNX Touch 
Diagnostics. For additional information on the first two methods refer 
to the LYNX Touch L7000 Series Installation and Setup Guide P/N 
800-16082 or higher.  

Register through LYNX Touch Diagnostics 

To Register the Communications Module, you must enter 
Programming Mode. 
1.  Select the “Comm. Diagnostics” button. 
2.  Select the “Setup Communications” button. 
3.  Select the “Register Device” button. The registration message is 

sent and the unit waits for the acknowledgement. (Refer to the 
LYNX Touch Installation and Setup Guide P/N 800-16082 or 
higher for additional information) 

 
 

 

10.  Program User Functions 

To perform these functions, you must enter the Master User 
Programming mode. 

Add Users 

1.  Select the “Users” button. 
2.  Select the “Add New”

 button. 

3.  Enter a User Name. 
4.  Enter a 4-digit User Code. 
5.  Select “Done”. 

Change the Master User Code 

1.  Select the “Users” button. 
2.  Select the “Master” button. 
3.  Select the “Edit”

 button. 

4.  Enter a new 4-digit User Code. 
5.  Select “Done”. 

Change/Edit Users or User Codes 

1.  Select the “Users” button. 
2.  Select the applicable “User” button. 
3.  Select the “Edit”

 button. 

4  Revise the User name, if applicable, then select “Done”. 

5.  Enter a new 4-digit User Code, if applicable, then select “Done”. 

Delete User Codes 

1.  Select the “Users” button. 
2.  Select the applicable “User” button. 
3.  Select the “Delete”

 button. 

4.  Enter a new 4-digit User Code. 
5.  Select “Yes” when the confirmation screen appears. 

 

11.  Test the system 

To perform this function, you must enter the Installer OR 
Master User Programming mode. 

1.  Select the “Test” button or icon. 
2.  Select the “Walk Test” button or icon.

 

3.  Open each protected door and listen for three beeps from the 

keypad, followed by the zone’s Voice Descriptor. Identification of 
each faulted protection point should appear on the display, and 
clear when the door is closed. 

4.

  

Walk in front of the motion sensor and listen for three beeps and 
the zone’s voice descriptor.  

5.  When testing is complete, enter an OFF sequence.  