FEATURES
This section provides an overview of the
VITALERT 2000 functions and capabilities.
Detailed descriptions appear in subsequent
sections of this manual. Refer to Figure 1 for
an illustration of the VITALERT 2000 front
panel.
Monitoring Display
The VITALERT 2000 features a 7-inch
diagonal amber CRT for the display of
waveforms, data, and alarm messages. The
keys which affect the monitoring display are
arranged in specific groups to the right of
the display screen. Four soft keys beneath
the
monitoring
display
are
used
to
manipulate on-screen data.
Alarm Display and Annunciation
The VITALERT 2000 presents active
alarms at the bottom of the CRT in a
three-level display of Warnings, Cautions,
and Advisories. Any alarms generated are
indicated by a 12 character keyword
phrase in the appropriate category.
When operating as a stand-alone monitor,
the VITALERT 2000 uses non-obtrusive
sound patterns to annunciate active
alarms. These easily distinguished
patterns coincide with the NAD alarm
priority classification of Warnings,
Cautions, and Advisories. The VITALERT
2000 will only annunciate the highest
priority currently active alarm. Lower
priority alarm sounds are temporarily
suppressed to minimize the confusion and
nuisance caused by simultaneous alarms.
When interfaced to a host system such as
NARKOMED 3, NARKOMED 2B or
VITALERT 1000, VITALERT 2000 audio
alarms are disabled; the alarm condition is
annunciated through the host system.
Monitor Screen
The Monitor screen (Figure 3) presents
graphic and numerical information derived
from the ECG lead, the invasive blood
pressure transducers and the temperature
probes. The Monitor screen is organized into
six areas: the ECG display, the P1 Arterial
Blood Pressure display, the P2 Blood
Pressure
display,
the
T1
Temperature
display, the T2 Temperature display, and
the Alarm display.
ECG Display
The VITALERT 2000 can monitor three
standard bipolar ECG limb leads (I, II, III),
three augmented leads (aVR, aVL, aVF),
and a floating chest lead (V). The ECG
display contains:
•
ECG waveform
•
Heart Rate
•
Heart Rate Alarm Limits
•
Selected ECG Lead
•
ECG Scale with 1 mV Markings
•
Isoelectric
Line
Reference
(with
reference digits at the top and bottom to
indicate mV’s from isoelectric).
•
Flashing Heart Indicator (if selected).
Invasive Blood Pressure Display
The VITALERT 2000 can monitor two
channels of invasive blood pressure. The P1
Pressure display is labeled for arterial
pressure (P1 ART). The P2 Pressure display
can be labeled for either central venous
pressure
(P2
CVP),
pulmonary
artery
pressure (P2 PA), or as a second arterial
pressure channel (P2 ART).
3