Quintaflex R96
Ceiling, Wall Model
Dr. Mach
Lamps and Engineering
59250001
Edition 01
21.02.2002 / Bak Page
12/18
4. Maintenance
The lamp has been designed and built so that regular maintenance intervals are not necessary.
In order to keep the system easy running throughout its life span, we recommend that the hinges be
greased once a year with an acid-free grease.
4.1 Adjustments at the ceiling
attachment
♦
Adjusting the spring arm
Note:
Maximum additional load at spring arms: Spring
arms are equipped with different springs to
compensate the lamp / device weight.
To adjust the spring force make sure that the spring
arm with the lamp / device can come to rest in any
desired position.
•
A hole
1
is located at the position marked by
detail
X
.
•
Position the spring arm
2
with the lamp / device
approximately 10° above horizontal.
•
Insert Allan key (width 5, included in the scope
of supply) into the hole
1
.
If the spring arm drops, the spring force is too low:
-
Rotate the adjustment screw to the
left
(counter
clockwise) in the
+
direction.
If the spring arm rises, the spring force is too high:
-
Rotate the adjustment screw to the
right
(clockwise) in the
-
direction.
If the spring arm with the lamp / device cannot
come to rest in any desired position after the
spring force has been adjusted, the springs must
be replaced by a service technician.
10°
-
+
2
1
X
Hole 1
Width 5