55 / 96
A B C D
E
F
G H
I
Possible cause
Remedy
-
-
-
-
-
-
✘
-
✘ 24 V supply overloaded
Disconnect frequency inverter from the power supply and
eliminate the cause of the overload.
-
-
-
-
-
-
-
-
✘ Dry running
Check the hydraulic system and rectify the fault on the
frequency inverter.
-
-
-
✘
-
✘
-
-
✘ Sensor signal error (e.g. broken
wire)
Check sensor and sensor cable.
-
✘
✘
-
-
-
-
-
✘ Phase failure (drive)
Check motor connection and stator winding.