39 / 96
6.2.4.2 Fluid temperature
Table 12:
Temperature limits of the fluid handled
Permissible fluid temperature
Value
Maximum
+60 °C
+25 °C to DIN 1988 (DVGW)
3)
Minimum
0 °C
6.2.5 Minimum flow rate
Table 13:
Size
Minimum flow rate per pump
[l/h]
DPV 2
200
DPV 4
400
DPV 6
600
DPV 10
1100
DPV 15
1900
DPV 25
2800
DPV 40
4600
DPV 60
6100
DPV 85
8500
DPV 125
12500
6.3 Shutdown
6.3.1 Stopping
1. Set the master switch to 0.
2. Set the manual-0-automatic selector switch to 0.
3
Applies to the handling of drinking water (Germany and the Netherlands only)
Содержание Hydro-Unit Utility Line F
Страница 29: ...29 96 1 2 Fig 12 PE connection 1 Earthing terminal 2 Location of power connection ...
Страница 58: ...58 96 ...
Страница 92: ...92 96 T Tank 79 Timers 73 W Warnings 9 Warranty claims 7 ...
Страница 93: ......
Страница 94: ......
Страница 95: ......