d i s A s s E M b L y / R E A s s E M b L y

pump maintenance checKlist

CHECK DAILY:

 Check  regulator  pressure  *  suction  =  Approx . 

1. 

5 bar (75 PsI) * Discharge = Approx . 2 .8 bar (40 
PsI)  (settings  vary  greatly  with  product  and 
Distance) .

 Check  filter  bowls  for  condensation  build-up  or 

2. 

damaged/dirty filters .

Check to make sure diffuser screen is in place

3. 

 Check to make sure the door of the control panel 

4. 

is closed and latched at all times to guard against 
water  ingress .  Lock  the  panel  door  closed  if 
necessary .

CHECK MONTHLY:

Check  vacuum generator function

1. 

 Disconnect  vacuum  line  at  senor  cap  and 

a. 

block off or cap the line .

 With  the  pump  turned  on  and  in  suction 

b. 

mode  a  vacuum  will  build  in  the  line  which 
can be read from the gauge on the vacuum 
generator .

 With 5 bar (75 PsI) line pressure the generator 

c. 

should  develop  between  22-26  inches  of 
vacuum .    If  it  is  found  that  the  generator  is 
not performing properly a rebuild or cleaning 
may be needed .

Inspect sensor cap including

2. 

All attached air lines

a. 

sensor cord

b. 

Pneumatic cylinders 

c. 

Fasteners 

d. 

O-ring seals

e. 

Inspect control cabinet including

3. 

Door latches

a. 

Door seal

b. 

PLC is securely mounted

c. 

All  cord  grips  and  bulkhead  fittings 

d. 

tightened

Check for air leaks

e. 

Check for corrosion

f. 

Potentiometer functions correctly

g. 

run/purge switch functions correctly

h. 

Valves function correctly

i. 

S e c t i o n   5

d i s A s s E M b L y / R E A s s E M b L y

pump cleaning procedure

 empty the discharge piping of product using the 

1. 

purge switch on the control panel .

 Disconnect inlet and outlet piping from the pump, 

2. 

keeping clamps and gaskets in a secure place .

 remove  sensor  cap  and  diffuser  screen  from 

3. 

pump and place them on the sensor cap storage 
bracket, keeping the clamp and gasket in a secure 
place .  By  hand,  wash  the  sensor  cap,  paying 
special  attention  to  the  probe .  An  abrasive  hand 
pad can be used to scour the probe if necessary .  
Avoid high pressure spray .  sanitize as necessary 
and inspect for cleanliness .

 Air  lines  to  and  from  pump  probe  be  inspected 

4. 

regularly and replaced as required .

 Air  lines  to  and  from  pump  probe  be  inspected 

5. 

regularly and replaced as required .

 remove reservoir tube from pump base, keeping 

6. 

clamp  and  gasket .    use  high  pressure  spray  to 
clean the tube . sanitize as necessary and inspect 
for cleanliness .

 remove  inlet  and  outlet  check  valves  from  the 

7. 

pump  base,  keeping  clamps  and  gaskets  in  a 
secure  place .    High  pressure  spray  as  well  as 
hand washing should be used to ensure thorough 
cleaning .  sanitize  as  necessary  and  inspect  for 
cleanliness .

 Clean  the  pump  base  with  high  pressure  spray .  

8. 

sanitize as necessary and inspect for cleanliness .

 By hand, wash all clamps and gaskets . sanitize as 

9. 

necessary and inspect for cleanliness .

 reassemble pump .

10. 

10

WILDEN PUMP & ENGINEERING CO., LLC

WIL-12120-E-01

Содержание WILDEN Saniflo VC4

Страница 1: ...R e f i n e y o u r p r o c e s s Engineering Opera ti o n Maint e n a n ce Saniflo Series METAL Pumps VC4 VC6 VC8 WIL 12120 E 01 ...

Страница 2: ...ribution System 3 Section 4 Dimensional Drawings 4 Section 5 Suggested INSTALLATION OPERATION TROUBLESHOOTING 5 Section 6 Assembly 9 Section 7 Exploded View Parts Listing sANIFLOtm VC4 12 sANIFLOtm VC6 14 sANIFLOTM VC8 16 VC Pump controller 18 Section 8 vc pump controller schematic 20 ta b le o f c o n te n t s ...

Страница 3: ... CAUTION The Saniflo VC pump is not submersible Mount control panel where it is not directly in the wash down area CAUTION Always wear safety glasses when operat ing pump If rupture of wetted components occurs material being pumped may be forced from pump and may create a hazardous situation CAUTION Before any maintenance or repair is attempted the compressed air line to the pump should be disconn...

Страница 4: ...Designation Max Solids Passage Inlet Dim Outlet Dim Est Shipping Wt 81 1000 VC4 SS SS FB 76 2 mm 3 76 mm 3 76 mm 3 41 7 kg 92 lbs 81 1002 VC4 SS SS TF 76 2 mm 3 76 mm 3 76 mm 3 41 7 kg 92 lbs 81 1004 VC6 SS SS FB 101 6 mm 4 102 mm 4 102 mm 4 48 9 kg 108 lbs 81 1006 VC6 SS SS TF 101 6 mm 4 102 mm 4 102 mm 4 48 9 kg 108 lbs 81 1008 VC8 SS SS FB 152 4 mm 6 125 mm 6 125 mm 4 69 9 kg 154 lbs 81 1010 VC...

Страница 5: ...ay from the internal vacuum generator s and directed into the vertical column of the pump Once the compressed air is supplied to the top of the process medium the hydraulic force will discharge the pro cess medium from the vertical column These same forces will close the inlet flap valve and open the discharge flap valve simultaneously causing the pro cess medium to move downstream FIGURE 3 The di...

Страница 6: ...381 15 C 157 6 18 N A N A N A N A D 304 12 304 12 304 12 E 101 4 152 6 203 8 F 1486 58 50 1505 59 25 1559 61 38 G 76 3 101 4 102 4 H 76 3 101 4 152 6 J 254 10 254 10 254 10 K 436 17 18 555 21 87 647 25 50 L 352 13 87 352 13 87 352 13 87 S e c t i o n 4 DI M E NSION A L D R A W INGS S A NI F L O T M V C REV A 4 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 7: ... including pumping distance required flow rate product viscosity and piping size ELECTRICAL The control panel requires 120 220VAC at 1 amps ELEVATION Selecting a site that is well within the pump s dynamic lift capability will assure that loss of prime troubles will be eliminated In addition pump efficiency can be adversely effected if proper attention is not given to site location PIPING Final de...

Страница 8: ... from the pump The Adjustable Probe During operation certain products can coat the sensor probe creating false inputs to the control panel and causing poor performance Periodic cleaning of the sensor probe may be required in certain applications to maintain reliability To decrease the frequency of cleanings the HPVC control panel has an adjustable probe set point This set point can be changed on t...

Страница 9: ... be displayed until the condition is corrected and the pump control is reset This screen alerts the operator to the nature of the problem and provides instructions to solve the problem and restart the pump This screen indicates that product has been in contact with the probe for a period of time that was unexpectedly long To identify the cause the operator should make sure that Air shut off valve ...

Страница 10: ...ow or no air pressure 2 Air valves not functioning properly 3 Dirty or defective vacuum generator 4 Loose connection on piping 5 Check valves misaligned 6 Solution Manually discharge the pump for 2 seconds to clear 1 any blockage If this does not help disassemble the pump and clear the check valves Turn up suction regulator to 5 bar 75 PSI 2 Check to ensure that the air supply is adequate 3 Disass...

Страница 11: ... 2 Begin assembly by installing the flange gasket and inlet flap valve housing to pump base After joining components secure with clamp band NOTE When installing inlet flap valve housing ensure that hinged portion of flap valve is located in the up position by utilizing the UP reference mark on the inlet housing Figure 2 Step 3 Figure 3 Position flange gasket and discharge flap valve housing to pum...

Страница 12: ...ons correctly g Run purge switch functions correctly h Valves function correctly i Pump Cleaning Procedure Empty the discharge piping of product using the 1 purge switch on the control panel Disconnect inlet and outlet piping from the pump 2 keeping clamps and gaskets in a secure place Remove sensor cap and diffuser screen from 3 pump and place them on the sensor cap storage bracket keeping the cl...

Страница 13: ... to the off position and 4 attach a proper lockout device After attaching the lockout devices put the keys in 5 your pocket After locking out the electrical and air supplies try to 6 start the pump to verify that it is properly disabled If the pump starts or still has power applied stop and get your supervisors help Release any stored air in the pump by turning the 7 regulator adjusting knobs full...

Страница 14: ...S e c t i o n 7 E x pl o d e d V i ew P art s L i s t i n g 6 6 6 5 1 2 4 5 3 5 5 SANIFLOTM VC4 E X P L OD E D V I E W 12 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 15: ...Inlet Check 3 x 3 1 80 0144 80 0144 3 Valve Outlet 4 x 3 Reducer 1 80 0145 80 0145 4 Base 4 Pump 1 80 0084 80 0084 5 Gasket 4 FB Buna 4 N A 80 0101 5 Gasket 4 Teflon 4 80 0152 N A 6 Clamp 4 H D 4 80 0089 80 0089 E x pl o d e d V i ew P art s L i s t i n g SANIFLOTM VC4 part s l i s t i n g 13 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 16: ...7 5 1 8 8 6 8 6 2 4 3 6 S e c t i o n 8 E x pl o d e d V i ew P art s L i s t i n g SANIFLOTM VC6 E X P L OD E D V I E W 14 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 17: ...t 6 x 4 Reducer 1 80 0147 80 0147 4 Base 6 Pump 1 80 0085 80 0085 5 Gasket 4 FB Buna 1 N A 80 0101 5 Gasket 4 Teflon 1 80 0152 N A 6 Gasket 6 FB Buna 3 N A 80 0102 6 Gasket 6 Teflon 3 80 0153 N A 7 Clamp 4 HD 1 80 0089 80 0089 8 Clamp 6 HD 3 80 0090 80 0090 E x pl o d e d V i ew P art s L i s t i n g SANIFLOTM VC6 part s l i s t i n g 15 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 18: ...1 7 5 3 6 8 2 4 6 8 8 6 S e c t i o n 8 E x pl o d e d V i ew P art s L i s t i n g SANIFLOTM VC8 E X P L OD E D V I E W 16 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 19: ...t 4 Teflon 1 80 0152 N A 6 Gasket 8 FB Buna 3 80 0151 80 0151 6 Gasket 8 Teflon 3 80 0154 80 0154 7 Clamp 4 H D 1 80 0089 80 0089 8 Clamp 8 H D 3 80 0150 80 0150 NOTE The VC8 pump is also available with a 152 mm 6 pump discharge connection To order this other option use item number 81 1011 To order an 8 x 6 outlet reducer for a VC8 pump use item number 81 0149 E x pl o d e d V i ew P art s L i s t...

Страница 20: ...S e c t i o n 8 E x p l o d e d V i e w Pa r t s L i s t i n g vc pump controller E XP L OD E D V I E W 18 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 21: ...GULATOR GAUGE 28 1 81 12153 8 VACUUM GENERATOR 29 1 81 12286 VACUUM GENERATOR GAUGE 30 1 81 12287 VACUUM GENERATOR MUFFLER 31 1 81 17792 1 4 NPT X 1 4 TUBE SWIVEL 90 32 1 81 12206 SS 1 4 STREET ELL 33 1 81 10938 SS 1 4 CLOSE NIPPLE 34 2 81 11900 SS 1 2 X 1 4 BUSHING 35 3 81 18348 SS 1 2 CLOSE NIPPLE 36 1 81 12497 SS 1 2 CROSS 37 1 81 13883 SS 1 2 BALL VALVE 38 1 81 17779 1 2 NPT X 1 2 TUBE STRAIGH...

Страница 22: ...S e c t i o n 8 v c p u mp c o n tr o ller s c hemat i c 20 WILDEN PUMP ENGINEERING CO LLC WIL 12120 E 01 ...

Страница 23: ...comes first Failure due to normal wear misapplication or abuse is of course excluded from this warranty Since the use of Wilden pumps and parts is beyond our control we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any...

Страница 24: ...nce The result of advanced thought Refine Your Process Designed for sanitary applications Minimize product degradation Improved production yields Easy to inspect clean assemble Minimized water requirements The result of progressive thought Simplify Your Process Maximize Your Process Electronic control monitoring Level control containment Pulsation dampening Drum unloading systems Complete system s...

Отзывы: