Page 14
Hydro Systems Co. 2019
HYD10099044 Rev 1.4
Once the EvoBoost has been setup (as per setup section), the EvoClean units will be ready to operate in a wash cycle. The
EvoBoost will automatically run every time the EvoClean operates, through use of a built-in pressure switch. The EvoBoost
will shut off automatically once the EvoClean unit stops dosing.
Operating the EvoClean dispensers
7. operation
•
Verify that the pump is running smoothly without constant interruption.
•
Check inlet & outlet plumbing to ensure not leaks have formed.
•
Clean the unit with a damp cloth and remove dust, lint and dirt.
Every 3 Months
8. maintenance
ENSURE BOTH THE EVOBOOST & THE EVOCLEAN UNITS ARE ISOLATED (POWER & WATER)
AND DE-PRESSURISED BEFORE SERVICING OR MAINTAINING EITHER UNIT.
Every 6 Months
Clean the pump pickup tube & use a cleaning tablet to clean the inside of the tank:
Remove securing clip for pickup tube
Remove hose using handle
WARNING TAKE CARE NOT
TO DROP THE PICKUP HOSE INTO THE WATER TANK
Remove Rear cover using flathead screwdriver to
CAREFULLY pry the lower clips open.
Remove rear cover
1
2
3
4
Содержание HYDRO EvoBoost