Bosch CM710B Скачать руководство пользователя страница 1

CM710B
4 Way Output Expander Module

Security System

Installer Reference Guide

EN

Security Systems

Содержание CM710B

Страница 1: ...CM710B 4 Way Output Expander Module Security System Installer Reference Guide EN Security Systems ...

Страница 2: ...up A dedicated service keypad and tamper input are provided If the tamper input is not required you should fit the supplied shunt to the tamper input pins To assist with installation the module includes indicators to show module and individual output status at all times A four way dip switch is used to select the output expanders address The address setting determines the output numbers for each e...

Страница 3: ...s Setting Output Numbers SW1 SW2 SW3 SW4 Control Panel 1 to 4 1 OFF OFF OFF OFF 5 to 8 1 x CM710B can be fitted to the Solution 16i panel Table 2 CM710B Address Configuration On Solution 16i Panel Solution 144 and Solution E Panels Module Number Address Setting Output Numbers SW1 SW2 SW3 SW4 Solution 144 Panel Solution E Panel Control Panel 1 to 5 Virtual Outputs 6 to 8 1 OFF OFF OFF OFF 9 to 12 2...

Страница 4: ...00 002 000 N Of 1 10 Seconds 000 000 000 000 000 000 Output Options Off On Low Battery Y Y N Y N N Guest Control N N N N N N Reserved N N N N N N Monitor Overload Y Y Y Y N N Monitor Device Fail Y Y N Y N N Alarm On Device Fail N N N N N N Block If All On N N N N N N Show Status On Keypad N N N N N N Show Status On Keypad N N N N N N Table 4 Solution 144 and Solution E Output Defaults Zone Allocat...

Страница 5: ... 2 Ur 36 External Audible A 71 CLI Trigger CLI 11 Dialler Disabled P 37 Internal Audible A 72 GSM Signal Lost P 12 Output Device Missing P 38 Any Zone Alarm A 73 GPRS Failure P 13 Output Trouble Op 39 Fire Alarm A 74 Ethernet Fail P 14 Panel On Line P 40 Burglary Alarm A 75 Macro Ma 15 Incoming Call P 41 Silent Alarm A 16 System Trouble P 42 Duress Alarm A 17 Box Tamper Zn 43 Keypad Medical A 18 Z...

Страница 6: ...o a unique address via this switch Tamper Connection Fit shunt if tamper not required i Note When controlling inductive loads such as Door Strikes always install protection diodes as shown Note the Cathode or marked end of the diode connects to the positive voltage When using the outputs to switch power from an external power supply you must only connect the negative of the power supply to the neg...

Страница 7: ...he table below list the default values for all output parameters in the Solution 16i panel Outputs 1 to 4 are high current digital outputs Outputs 5 to 8 are only available if the optional output expander board CM710B is fitted Options marked N A Not Applicable Solution 16i Default Output Programming Programming Option Output 1 Output 2 Output 3 Output 4 Output 5 8 Output Name External Siren Strob...

Страница 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems CM710BIRG Issue FTR1 3 ...

Отзывы: