Faults -5
Version 1.36
02/2004
Only half cups (portion control) or long time needed to fill a cup (cont. flow)
Cause
Action
Ref.
1.
Tube(s) of the inlet valve is/
Open left cover and check the in/outlet tubes
are partially disconnected or
of the inlet valve. When partially disconnected
squeezed when the left
leakage at the right machine side will also
PL-3
cover was closed
occur.
2.
Outlet tube clogged, not
Remove left cover and check tubes and nozzle.
connected to the nozzle
This malfunction implicates that water is leaking
or clogged nozzle
at the left side of the machine.
5A-6 / PL-3
Only water is poured when the coffee button is pressed.
Cause
Action
Ref.
1.
Failing empty detection.
Coffee inside pack/dosing tube is clogged.
(LED does not light up)
Replace the pack
The circular opening in the base through which the
dosing tube is guided is dirty. Clean if necessary.
The empty detection assembly is defective.
Replace if necessary
5C-1 / PL-8
Control PCB malfunction or the connector/wiring is
loose. Check connections.
5K-6
Irregular / Faulty Coffee strength
Cause
Action
Ref.
1.
Outlet valve malfunction
Connect service device and test product valve.
4-4
(blocked)
Check if water is flowing out of the trough.
Replace valve if necessary
5A-6 / PL-3
2.
Boiler not filled quickly
Water supply is irregular due to scaling of inlet valve,
enough
scale inside hoses or clogged sieve. Check dispensed
water volume and check/replace valve/hoses.
5A-7 / 5A-8
3.
Tube between inlet valve
Open left cover and check/correct. Always close left
and boilers queezed
cover carefully in order not to squeeze/disconnect tube.
4.
Irregular coffee concentrate
The coffee pack is not well defrosted. Defrost.
dosing
The concentrate quality is affected. (old)
Check expiry date, replace coffee pack if necessary.
Coffee pack is not shaken before use. Shake pack well.
5.
Inlet valve not calibrated
Calibrate the inlet valve
5A-3
Содержание Cafitesse 50
Страница 4: ...Version 1 36 02 2004 ...
Страница 20: ...Version 1 36 02 2004 ...
Страница 30: ...Version 1 36 02 2004 ...
Страница 38: ...Programming 8 Version 1 36 02 2004 4 3 Programming flow chart service device ...
Страница 56: ...Version 1 36 02 2004 ...
Страница 64: ...Version 1 36 02 2004 ...
Страница 78: ...Version 1 36 02 2004 ...
Страница 80: ......
Страница 94: ...Version 1 36 02 2004 ...
Страница 95: ...Version 1 36 02 2004 6 Preventive Maintenance Contents 02 2004 Not available ...
Страница 96: ...Version 1 36 02 2004 ...
Страница 102: ...Version 1 36 02 2004 ...
Страница 103: ...Version 1 36 02 2004 8 Service Information Bulletins Contents 02 2004 Not available ...
Страница 104: ...Version 1 36 02 2004 ...
Страница 105: ...Version 1 36 02 2004 9 Modification Instructions Contents 02 2004 Not available ...
Страница 106: ...Version 1 36 02 2004 ...