Faults -7
Version 1.36
02/2004
Water leakage - Machine left side.
Cause
Action
Ref.
1.
Inlet valve scaled
Inlet valve does not close properly due to scale and the
5A-7 / 5A-8
boiler overflows. Check replace inlet valve. Check also
PL-3 / PL-10
the water hose for scale when the inlet valve is
replaced, as this scale may cause instant reoccurrence.
2.
Tube between inlet valve
Open left cover and check/correct. Always close left
and boilers queezed
cover carefully in order not to squeeze/disconnect tube.
3.
Machine has overboiled or
Reset the machine. Unplug the power cord when
hot water has entered the
before touching the reset switch.
overflow tube
4.
Damaged boiler
Check inlet of drain hose / inlet hose for small cracks.
Check connection between upper/lower part (welded).
Check front boiler leg for presence of cracks.
Replace boiler if necessary.
5A-1 / PL-4
5.
Water level probe fault
Check probe and its connections. Check if the GND
5A-5
(overflow)
is connected.
Check boiler connector (24VDC)
5A-1(Illustr.)
Connect if necessary.
Heating element wiring not connected : no GND for
level probe pulse. Connect if necessary.
PL-4
6.
Boiler lid sealing not well
Condensated water leaks through the sealing. Check
5A-5 / PL-4
the isolation at the side of the boiler opposite of the
frame for traces of water/scale.
7.
Outlet valves not correctly
Check / Correct.
installed
8.
Outlet tubes not connected
Check / Connect.
to nozzle
9.
Boiler overflow (failing level
Measure restistance between black (GND) wire of the
SI038
detection due to poor power
power board connector and the black (GND) at the back
board GND connection
side of the board.
If > 0 Ohm, replace power PCB.
If 0 Ohm
, check Resistance between one of the black
(GND) wires and the lead (GND) in the middle of the
heating element plug. If >0 Ohm check
connections/wiring
Содержание Cafitesse 50
Страница 4: ...Version 1 36 02 2004 ...
Страница 20: ...Version 1 36 02 2004 ...
Страница 30: ...Version 1 36 02 2004 ...
Страница 38: ...Programming 8 Version 1 36 02 2004 4 3 Programming flow chart service device ...
Страница 56: ...Version 1 36 02 2004 ...
Страница 64: ...Version 1 36 02 2004 ...
Страница 78: ...Version 1 36 02 2004 ...
Страница 80: ......
Страница 94: ...Version 1 36 02 2004 ...
Страница 95: ...Version 1 36 02 2004 6 Preventive Maintenance Contents 02 2004 Not available ...
Страница 96: ...Version 1 36 02 2004 ...
Страница 102: ...Version 1 36 02 2004 ...
Страница 103: ...Version 1 36 02 2004 8 Service Information Bulletins Contents 02 2004 Not available ...
Страница 104: ...Version 1 36 02 2004 ...
Страница 105: ...Version 1 36 02 2004 9 Modification Instructions Contents 02 2004 Not available ...
Страница 106: ...Version 1 36 02 2004 ...