Faults -4
Version 1.36
02/2004
Only coffee concentrate is poured when the cup/pot coffee selection button is pressed.
Cause
Action
Ref.
1.
Outlet valve malfunction
Connect service device and test product valve.
4-4
(blocked)
Check if water is flowing out of the trough.
Replace valve if necessary
5A-6 / PL-3
2.
Outlet tube clogged, not
Remove left cover and check tubes and nozzle.
connected to the nozzle
This malfunction implicates that water is leaking
or clogged nozzle
at the left side of the machine.
PL-3
3.
Flat cable is damaged
Check the flat cable (remove right cover) and
5K3 / PL-6
or disconnected
replace cable (incl.operation PCB) if necessary.
4.
The valves are
Check the wiring and the connectors of the
5A-6 / PL-3
incorrectly connected.
product valve(s).
5.
Control PCB failure
If the machine pours only coffee concentrate
without apparent reason, the control PCB may
be defective. Check output voltages
5K-6
and replace if necessary
5K-1 / PL-2
no hot water is poured when the hot water selection button is pressed.
Cause
Action
Ref.
1.
Outlet valve malfunction
Connect service device and test product valve.
4-4
(blocked)
Check if water is flowing out of the trough.
Replace valve if necessary
5A-6 / PL-3
2.
Outlet tube clogged, not
Remove left cover and check tubes and nozzle.
connected to the nozzle
This malfunction implicates that water is leaking
or clogged nozzle
at the left side of the machine.
PL-3
3.
Flat cable is damaged
Check the flat cable (remove right cover) and
5K-3 / PL-6
or disconnected
replace cable (incl.operation PCB) if necessary.
4.
The valves are
Check the wiring and the connectors of the
incorrectly connected.
product valve.
5A6 / PL-3
5.
Control PCB failure
If the machine pours only coffee concentrate
without apparent reason, the control PCB may
be defective. Check output voltages
5K-6
and replace if necessary
5K-1 / PL-2
Actual pot volume is far less than the preset 900 ml
Cause
Action
Ref.
1.
Water tank is empty before
See the table on page 3 and change setting
total volume was dispensed
if necessary. (LED will also light on)
2.
The boiler temperature
See the table on page 3 and change setting
dropped during delivery
if necessary. (LED will also light on)
PL = Parts list (Section 10)
Содержание Cafitesse 50
Страница 4: ...Version 1 36 02 2004 ...
Страница 20: ...Version 1 36 02 2004 ...
Страница 30: ...Version 1 36 02 2004 ...
Страница 38: ...Programming 8 Version 1 36 02 2004 4 3 Programming flow chart service device ...
Страница 56: ...Version 1 36 02 2004 ...
Страница 64: ...Version 1 36 02 2004 ...
Страница 78: ...Version 1 36 02 2004 ...
Страница 80: ......
Страница 94: ...Version 1 36 02 2004 ...
Страница 95: ...Version 1 36 02 2004 6 Preventive Maintenance Contents 02 2004 Not available ...
Страница 96: ...Version 1 36 02 2004 ...
Страница 102: ...Version 1 36 02 2004 ...
Страница 103: ...Version 1 36 02 2004 8 Service Information Bulletins Contents 02 2004 Not available ...
Страница 104: ...Version 1 36 02 2004 ...
Страница 105: ...Version 1 36 02 2004 9 Modification Instructions Contents 02 2004 Not available ...
Страница 106: ...Version 1 36 02 2004 ...