Lit. No. 76348, Rev. 01
26
May 15, 2017
FILL TANK SIZE:
Selecting the VOLUME position
on page one (1) allows
the user to enter a
FILL TANK SIZE
which can be toggled
to OFF or 1 to 65535 using the
"+" or
"
−
"
(reset) keys. The FILL TANK SIZE
is in gallons in English or liters if in
Metric Units. If a FILL TANK SIZE is
specified, then pressing
"+"
while set
to the
TANK
position (in Operation) will set the TANK
value to FILL TANK SIZE for quick reloading.
FLOW
CAL
VOLUME
(1) (2) (3)
TANK ALARM SET POINT:
Selecting the
VOLUME/MINUTE
position on page one
(1) allows a TANK
ALARM SET POINT to be entered.
When enabled, the Warning LED
flashes, the alarm sounds and the
display alternates between FILL and normal when
Tank volume falls below the Set Point. When set to
"OFF", the alarm is disabled.
MIN
FLOW
VOLUME /
MINUTE
BLAST TARGET RATE:
Selecting the RATE position on page
one (1) allows the user to enter the
desired BLAST TARGET RATE. The
units and range are identical to the
normal TARGET
RATE but BLAST
TARGET RATE is
only used when the
BLAST
key is pressed.
BLAST DURATION:
Selecting the TANK LEVEL position on
page one (1) allows the user to enter the
desired BLAST
DURATION. It
can be adjusted
from 0 (OFF) to
255 seconds.
TARGET
RATE
RATE
ADJUST
RATE
TANK LEVEL
"SPECIAL" CALIBRATION (CONT.)
Entering Calibration Values (cont.)
Page One
UNITS (English or Metric):
Selecting the AREA
position on page
one (1) allows the
user to change the UNITS
and load
defaults.
Pressing the
"+" or "
−
"
(RESET) keys will toggle between English
and Metric UNITS and the display will
show En9 or nnEt. NOTE: Trying to select
Metric Units in Turf Mode will cause the Error message to be
displayed. Defaults will not be loaded until the Rotary
Selector is moved away from AREA or the "Special"
Cal page is changed or "Special" Cal is exited normally.
WIDTH
CAL
AREA
(1) (2) (3)
VEHICLE NUMBER:
Selecting the
DISTANCE
position on page
one (1) allows the user to change the
VEHICLE NUMBER from 0 to 255 by
using the
"+" or "
−
"
(Reset) keys. The
VEHICLE NUMBER is downloaded with the Total and
Configuration data through the serial port.
SPEED
CAL
DISTANCE
(1) (2) (3)
VALVE POLARITY:
Selecting MODE position on page one
(1) allows the operator to install the flow
control valve in either a By-Pass or In-
Line configuration.
Pressing the
"+"
or "
−
"
(reset) key
will toggle the display between bYPAS and InLin.
MODE
(ALARM RESET)
MODE
SELECT
VALVE SPEED:
Selecting the SPEED position on
page one (1) allows VALVE SPEED
to be changed, to adjust system
response speed (if required). Pressing
the
"+" or "
−
"
(Reset) keys will adjust
the VALVE SPEED from –4 to 3.
Normal setting is –1.
NOTE: Use caution
when adjusting the
Valve Speed setting. Higher values used with a
fast valve may cause system instability (hunting,
oscillations).
TEST
SPEED
SPEED
(1) (2) (3)
NOTE: Changing UNITS will load defaults, so they
should always be changed first and then all other
CALIBRATE and "SPECIAL" CALIBRATE values
may be set.
OPERATING AND CALIBRATION INSTRUCTIONS