VOLUME/MINUTE:

 Displays total gal-

lons (liters) of liquid applied per minute.

WIDTH CAL: 

Enter the working width.

SPEED CAL: 

Enter the speed calibration number in 

inches (cm) per pulse.

MODE SELECT: 

Allows the user to change the MODE 

SELECT between modes of operation. Lane, Ag, Dust, 

and Turf.

TEST SPEED:

 Simulates ground speed for system 

checkout.

RATE:

 

Displays application rate.

FLOW CAL: 

Enter the calibration value assigned to your 

flowmeter (see flowmeter tag).

MIN FLOW: 

Enter the minimum flow rate of the 

application system.

ADJUST RATE: 

Enter an amount of change for on-the-

go adjustments to the target rate.

TARGET RATE:

 Enter the target application rate.

Calibration Positions

Calibration Positions

Rotary Switch Position Functions

KEYLOCK FUNCTION –

 When locked allows the user to 

view calibration values but prevents changes, allows Data 

Set 1 to be cleared but prevents clearing Data Sets 2 & 

3 (Volume, Area, Distance, Average & Highest Velocity).

TANK ALARM 

– Can be initiated by either the optional 

Tank Level Switch or the Tank Counter (if Tank Alarm is 

set in "Special" Calibration).

VOLUME (1) (2) (3)

: Displays total 

gallons (liters) of liquid applied. 

May be reset. SEE NOTE

AREA (1) (2) (3)

: Keeps a running 

count of the total area worked. May 

be reset. SEE NOTE

DISTANCE (1) (2) (3)

: Displays 

distance traveled. May be reset. 

SEE NOTE

MODE

: Displays selected mode. 

User selects between Lane, Ag, 

Dust, and Turf Modes of operation. 

Allows Audible Alarm to be RESET 

by Pressing the RESET button.

SPEED (1) (2) (3)

: Displays ground 

speed in miles per hour (kilometers 

per hour) or Average & Highest  

velocity. May be reset. SEE NOTE

TANK LEVEL:

 Displays gallons (liters) 

of liquid remaining. If a FILL TANK 

SIZE has been set to a value in Cali-

bration, pressing the 

"+"

 will make the 

Tank value jump to FILL TANK SIZE 

value. The value can be decreased 

but not increased above the FILL size. 

If the FILL TANK SIZE is set to Zero, 

Tank level can be adjusted to any 

value from 0 to 65,535 using the 

"+" 

or "−"

 (RESET) keys.

NOTE:

 

VOLUME, AREA, DISTANCE, & SPEED 

counters work in sets. If the VOLUME counter 1 is 

reset, it also resets AREA counter 1, DISTANCE 

counter 1 and Average & Highest Speed counter 1. This 

will be the same for resetting any counters in the set.

RoadMaster™ CONSOLE FUNCTIONS 

 

The RoadMaster features a large, easy-to-read liquid crystal display, rotary dial, and lighted panel for 

night use.

REMOTE BLAST SWITCH - Optional: 

The Optional 

Remote Blast Switch can initiate the BLAST sequence in 

normal operation, the same as the console BLAST switch.

AUDIBLE ALARM: 

Alarm will sound for Rate errors over 

10%, Tank Level below set point or Tank Empty (from Float 

input). The alarm can be temporarily shutoff by setting 

rotary switch to MODE (Alarm Reset) and pressing the 

RESET button. 

Note: Setting ALARM ENABLE to OFF 

in "Special" Calibration will disable All Audible Alarms.

WARNING LIGHT: Indicates over- or under-application 

of plus or minus 10% from the Target Rate or if the 

tank is low or minimum flow active. Also lit when in 

CAL and Unlocked.

 Multi-function key:

• Used to enter and exit the calibration and 

"special" calibration modes.

•  Used to initiate BLAST sequence in normal operations.

• 

Overrides flowmeter input in case of an Emergency Stop.

•  Toggles between SPEED CAL and Distance traveled while

fine tuning the SPEED CAL factor or between FLOW CAL

and Volume when fine tuning the Flow Cal factor.

See Appendices C & D.

Soft Key Functions

BLAST

Key which changes operation from automatic 

control to manual. (If Manual Control is enabled, 

see page 21.)

AUTO

MAN

PROGRAM KEYS: 

In normal operating 

modes, used to increase/decrease 

application rate. With Rotary Switch 

in the SPEED position, RESET key 

is used to display Average and Maximum Speed. In 

Volume, Area, Distance, or Speed, the 

"+"

 key selects 

counter set.

• 

RESET: When in HOLD and not in CAL, clears the 

selected counter 

set

 when held for two sec onds. When 

rotary switch is in the MODE position, Resets Audible 

Alarm.

  When in CAL, the "

+

" key increases and the "

decreases the calibration value displayed.

RESET

WIDTH

CAL

FLOW

CAL

MIN

FLOW

ADJUST

RATE

TARGET

RATE

SPEED

CAL

TEST

SPEED

VOLUME /

MINUTE

DISTANCE

(1) (2) (3)

MODE

(ALARM RESET)

VOLUME

(1) (2) (3)

RATE

SPEED

(1) (2) (3)

 AREA

(1) (2) (3)

TANK LEVEL

BLAST

AUTO

MAN

RESET

MODE

SELECT

OPERATING AND CALIBRATION INSTRUCTIONS

Содержание SnowEx Liqui Maxx

Страница 1: ...tion Instructions Original Instructions This manual and instructions are for Liqui Maxx Sprayer Systems with serial numbers beginning with 160518 and higher This document supersedes all editions with...

Страница 2: ......

Страница 3: ...soline 17 Adding Brine 17 OPERATING CALIBRATION INSTRUCTIONS 19 Control Operation 19 Deluxe RoadMaster Control 19 Standard RC 1B Control 20 RoadMaster Console Functions 21 Rotary Switch Position Funct...

Страница 4: ..._______ Outlet Address _______________________________________________________________________ Vehicle Model ________________________________________________ Year ________________ Equipment Model ____...

Страница 5: ...otentially hazardous situation that if not avoided could result in death or serious personal injury CAUTION Indicates a potentially hazardous situation that if not avoided may result in minor or moder...

Страница 6: ...take a unit off a truck with liquid in it Do not climb into or ride on the machine WARNING Securely bolt and strap unit into place on the vehicle bed using the optional UMK 200 bolt kit and ratchet s...

Страница 7: ...stem read the engine owner s manual if so equipped While operating the unit use auxiliary warning lights except when prohibited by law Tighten all fasteners according to the Torque Chart Refer to Torq...

Страница 8: ...including proper personal protective safety equipment FIRE AND EXPLOSION Be careful when using gasoline Do not use gasoline to clean parts Store only in approved containers away from sources of heat o...

Страница 9: ...Manual covers vehicles that have been recommended for carrying the sprayer system Please see your local dealer for proper vehicle applications CERTIFICATION WARNING Overloading could result in an acc...

Страница 10: ...rely fasten the 90 elbow to the tank bulkhead fitting Make sure the bulkhead fitting is securely fastened to the tank to prevent leaks Clock the 90 elbow so that the hose remains free of kinks and cut...

Страница 11: ...ween front of the truck bed and the tank base Make a spacer to fill between the tank base and the front of the truck bed Failure to install this spacer could result in damage to the sprayer and or veh...

Страница 12: ...or frame clamps to fasten the harness along the frame 2 Lay out the control power cable along the fire wall and fender well Do not connect the power leads to the battery yet 3 Route the control power...

Страница 13: ...Lit No 76348 Rev 01 13 May 15 2017 RoadMaster WIRING DIAGRAM INSTALLATION INSTRUCTIONS RoadMaster is a trademark of Micro Trak Systems Inc...

Страница 14: ...through the bracket holes from the inside out Place console over carriage bolt heads Install the switch brackets over the carriage bolts and alongside the console bracket Install the mount knobs on t...

Страница 15: ...valve connectors 10 Flow Control Section Harness Connect these connectors to corresponding valves Apply silicone grease to valve connections to avoid corrosion Connect the power to the RoadMaster cons...

Страница 16: ...s that output a pulsed signal such as the Micro Trak Astro 5 SkyTrak or Dickey John GPS speed sensors An adapter cable may be required Installing External BLAST Switch An optional external Momentary O...

Страница 17: ...he vehicle while the sprayer will be in use step bumper trailer hitch snowplows etc and fill gas tanks 3 Obtain the Gross Vehicle Weight Rating GVWR Front Gross Axle Weight Rating FGAWR and Rear Gross...

Страница 18: ...pen for spraying Filling with the Liqui Maxx sprayer s pump NOTE This method only works when the brine reservoir level is above the tank level The pump requires a gravity fed start to remove standing...

Страница 19: ...l sections ON and OFF For example instead of using the individual section switches simply use the RUN HOLD switch 3 Set the valves to the spray configuration Start the Liqui Maxx sprayer s motor by tu...

Страница 20: ...ng the vehicle battery turn OFF the control when not in use 3 When finished turn the motor OFF RoadMaster is a trademark of Micro Trak Systems Inc Standard RC 1B Control Follow the steps below to get...

Страница 21: ...work in sets If the VOLUME counter 1 is reset it also resets AREA counter 1 DISTANCE counter 1 and Average Highest Speed counter 1 This will be the same for resetting any counters in the set RoadMast...

Страница 22: ...e is in Units of Miles Km and Application Rate is in amount of liquid per Lane Mile Lane Km AGRICULTURAL Mainly used for roadside spraying where Area is in acres hectares Distance is in feet meters an...

Страница 23: ...sable this feature simply enter 0 for a val ue WIDTH CAL AREA 1 2 3 MIN FLOW The pur pose of this calibration setting is to prevent the system from applying below the recommended minimum flow rate for...

Страница 24: ...onfirm overall system performance SPEED CAL This position is used to calibrate the speed sensor for ac cu rate speed and dis tance measurement When this position is selected the display will show the...

Страница 25: ...PECIAL CAL pages 1 2 and 3 Number icons indicate page The desired Special Calibration Parameter s can then be accessed with the rotary switch To exit Special Calibration press and hold the BLAST butto...

Страница 26: ...on page one 1 allows the user to change the UNITS and load defaults Pressing the or RESET keys will toggle between English and Metric UNITS and the display will show En9 or nnEt NOTE Trying to select...

Страница 27: ...r to change the AUTO DELAY TIME by using the or Reset keys to vary the delay time from 0 no delay to 1 2 3 or 4 seconds START TIME Selecting the VOLUME MINUTE position on page two 2 allows the user to...

Страница 28: ...ANUAL key will not toggle between Auto and manual when set to ON ALARM ENABLE Selecting the RATE position on page three 3 allows the user to turn the audible ALARM ENABLE ON or OFF by using the or Res...

Страница 29: ...ter than 10 for 3 seconds continuously after the Auto Delay and Start Up time have completed and the console is in AUTO and the Ground Speed is above the Alarm Minimum Speed Emergency Stop When in AUT...

Страница 30: ...he small number will increment each time the button is pressed from 1 to 3 then rolls back to 1 DO NOT attempt to select the counter number by using the button because that will clear the active set o...

Страница 31: ...MODEL RC 1B STANDARD SPRAYER CONTROL Sprayer Console 1 Master Switch Switches power to the boom switches Always use this switch to cut off the entire boom 2 Boom Switches Three ON OFF switches for in...

Страница 32: ...F Auto Delay Time 1 sec Valve Polarity Bypass Auto Shut off ON Minimum Alarm Speed 0 MPH Manual Control Enable ON Alarm Enable ON Default Calibration Values English Mode Acres Speed Cal 0 189 Flow Cal...

Страница 33: ...8 1 47 11 8 1 68 13 4 Side Nozzle Width ft gal min 30psi Total gal min gal min 40psi Total gal min Red std 8 0 37 3 0 0 42 3 4 White std 8 0 72 5 8 0 84 6 7 Application calculations assume boom set 1...

Страница 34: ...16 Black Equations A Application rate in gallons per acre or gallons per lane mile S speed in miles per hour G flow rate of the nozzles in gal min See chart above for min and max values B Spray width...

Страница 35: ...cation rate of 30 gallons per acre Note that the boom application rate will not change Using the equation to solve for speed the variables are as follows Smax Unknown A 30 gal acre B 4 feet G 12 gal m...

Страница 36: ...of E I du Pont de Nemours and Company WARNING Inspect the unit periodically for defects Parts that are broken missing or worn out must be replaced immediately Do not alter any part of the unit without...

Страница 37: ...1 Check plug connection at cab control 2 Switched accessory connection is poor 2 Check accessory connection 3 Faulty battery 3 Check for low battery 4 Vehicle control harness is damaged 4 Replace or...

Страница 38: ...INT is properly calibrated Warn LED flashes when the Rate error is over 10 or Volume Minute is below the Minimum or Tank is less than Tank Set Point It is on steady when in CAL mode or SPECIAL CAL mod...

Страница 39: ...Lit No 76348 Rev 01 39 May 15 2017...

Страница 40: ...ement policy to change construction or design details and furnish equipment when so altered without reference to illustrations or specifications used TrynEx International LLC or the vehicle manufactur...

Отзывы: