![Dot Hill Systems SANnet II 200 Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/dot-hill-systems/sannet-ii-200/sannet-ii-200_installation-operation-and-service-manual_2524262121.webp)
Appendix B Cabling JBODs B-11
Note –
In a split-bus configuration, if each port is connected to a different server, the
program can only monitor the JBOD from the server connected to port B. SAF-TE
information is not displayed for port A.
B.8.2
Viewing Component and Alarm Characteristics
In SANscape, to view environmental component and alarm characteristics, use the
View Enclosure window or, for some components, the main window.
You can also view environmental and drive components using the SANscape CLI
show enclosure-status
command. For details, refer to the
SANscape CLI User’s
Guide
.
Main Window
In the main window, device states are color-coded and symbol-coded so that it is easy
to identify when a device is in a state that requires attention. The status is propagated
along the device tree, enabling you to trace a failure down to the device level. See
Table B-5
for device status details.
To view the cause of a critical or degraded device status, review the event log. For
details on the event log, refer to the
SANscape User’s Guide
.
Table B-5
Device Status State
Color
Symbol
State
Purple
None
The group, server, or device is online.
White
None
The user has not logged into this server.
Yellow
One or more components of this group or server are
not working properly, but the array is still functional.
Red
One or more components of this group or server are
not working. For instance, a disk drive failure or an
enclosure with a failed fan would warrant a critical
state icon.
Gray
The group, server, or device is unresponsive.
?
Содержание SANnet II 200
Страница 1: ...SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005 83 00002359 Revision C...
Страница 32: ...3 4 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 64: ...4 32 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 74: ...5 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 106: ...7 22 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 130: ...B 20 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 146: ...E 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 154: ...F 8 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 160: ...G 6 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 178: ...I 10 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 180: ...J 2 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...
Страница 186: ...6 SANnet II 200 SCSI Array Installation Operation and Service Manual June 2005...