GB
©
DOSATRON INTERNATIONAL /
37
©
DOSATRON INTERNATIONAL /
36
1 - When using soluble products to
be made up into solutions, we
recommend the periodic dis-
mantling of the entire
injection part (see : § CLEA-
NING AND REFITTING THE
SUCTION VALVE § CHAN-
GING SEALS IN THE
INJECTION ASSEMBLY).
Thoroughly rinse all the ele-
ments of the injection part
with water and re-assemble
them after having previously
lubricated the seal
(Fig. 7)
with a silicone lubricant, in the
case of difficulty in re-fitting.
2 - Before putting the DOSATRON
into operation after a non-use period,
remove the motor piston
and soak it into luke-
warm water < 40° C
overnight. This helps to
dissolve any deposits
which may have dried
onto the motor piston.
USING FOR THE FIRST TIME
- Switch the bypass button on the top of the DOSATRON to position ON.
- Operate the DOSATRON until the product to be injected is drawn up into the
injection stem (the product is visible through the plastic tube).
- The DOSATRON makes a characteristic “click-clack” noise when working.
NOTE :
The time required to prime the suction hose depends on the water
flow-rate, the ratio setting and the length of the suction hose. To bleed the
air from the suction hose and accelerate the priming, set the injection rate
at maximum. Once the DOSATRON is primed, adjust to the required injec-
tion rate (see § ADJUSTING THE INJECTION RATE).
INTEGRATED BY-PASS
Maintenance
RECOMMENDATIONS
Fig. 7
Seal
- By-pass in
ON
position : the DOSATRON is sucking, injecting and mixing
concentrate into water at the desired percentage.
- By-pass in
OFF
position : the DOSATRON is not working and is not drawing up
any concentrate.
FITTING THE SUCTION TUBE
If the DOSATRON has already been
used, please
imperatively refer to:
PRECAUTIONS.
1 - For D45RE1.5/IE and RE3/IE
- Unscrew the nut
(Fig. 8-E)
at the bot-
tom of the injection assembly and put
it onto the tube.
- Push the tube onto the barbed fitting
as far as it will go
and screw up the
nut
by hand
.
2 - For D45RE3000
- Unscrew the nut
(Fig. 8-G)
at the
bottom of the injection assembly and
put it onto the tube.
- Push the tube onto the barbed fitting
as far as it will go
and screw up the
nut
by hand
.
3 - For D45RE8/IE
- Loose the clamp
(Fig. 8-F)
holding
the suction hose by means of a screw-
driver.
- Push the hose onto the barbed fitting
as far as it will go and then fasten the
clamp again.
Putting the Dosatron
into order
E
G
F
Fig. 8
Содержание D 45 RE 1.5
Страница 2: ...Quick start up 1 1 2 2 Maxi 46 clics 15 sec...
Страница 74: ...DOSATRON INTERNATIONAL 144 DOSATRON INTERNATIONAL 145 SCHEMAS D 45 RE 1 5...
Страница 75: ...DOSATRON INTERNATIONAL 146 DOSATRON INTERNATIONAL 147 SCHEMAS D 45 RE 3...
Страница 76: ...DOSATRON INTERNATIONAL 148 DOSATRON INTERNATIONAL 149 SCHEMAS D 45 RE 8...
Страница 77: ...DOSATRON INTERNATIONAL 150 DOSATRON INTERNATIONAL 151 SCHEMAS D 45 RE 3000...
Страница 78: ...DOSATRON INTERNATIONAL 152 DOSATRON INTERNATIONAL 153 SCHEMAS D 45 RE 1 5 IE...
Страница 79: ...DOSATRON INTERNATIONAL 154 DOSATRON INTERNATIONAL 155 SCHEMAS D 45 RE 3 IE...
Страница 80: ...DOSATRON INTERNATIONAL 156 DOSATRON INTERNATIONAL 157...
Страница 81: ...DOSATRON INTERNATIONAL 158 DOSATRON INTERNATIONAL 159 SCHEMAS D 45 RE 8 IE...