Dorner Mfg. Corp.
12
851-738 Rev. A
Brushless DC Motor Control
Installation
External Input Signals
External input signals must be set in accordance with the desired application.
Perform the various settings specified below using the digital operator.
Input Signal Connection Terminals
Connect the input signals according to the operation method of your system. Dry contact signals are recommended. For solid
state signals see Oriental Manual for details.
Figure 23
Figure 23
Application
Necessary settings
Use input signals connected to terminals
X1, X2 and X3
Switch the operation-signal input method to “external input signals” on the
digital operator. See
“Switching the Signal Method to Remote Signal (If Required)”
Terminal
Position
Terminal
Name
Signal Name
Description
Necessary settings
Lower
Stage
C0
IN-COM0
Input signal common
Remove the short bar and connect an
external control equipment.
C1
IN-COM0
Input signal common
-
X1
CW input
Clockwise rotation
Set the operation-signal input method to
“external input signals” on the digital
operator.
X2
CCW input
Counterclockwise rotation
TH
TH
M0
M1
M2
VH
VM
VL
Y1
Y2
X0
Upper stage
Lower stage
C0
C1
X1
X2
X3
X4
X5
Y0
C2
Input signal common
ON: Clockwise rotation
OFF: Stop
ON: Counterclockwise rotation
OFF: Stop
Jumper X3 to Common
C3
Input signal
common (0 V)