background image

EN

GSR XEA BG

GSR-EMF XEA BG

Mounting instructions

Contents

About this manual 

2

1.1  Information about the manual 

2

1.2  Target groups 

2

1.3  Provided documents 

2

1.4  Symbols and abbreviations used 

2

1.4.1 

Safety instructions 

2

1.4.2 

Further labeling 

2

1.4.3 

Tool symbols 

2

1.5 Glossary 

2

2 Safety 

3

2.1  Intended use 

3

2.2  Limitation of liability 

3

2.3  Prerequisites for the operation of catching 

devices 

3

Product description 

3

3.1 EMF 

3

3.2  Technical data of the EMF 

3

4 Installation 

4

4.1  Prepare the mounting of the slide rail 

4

4.2  Mount the sliding rail of the fixed leaf 

4

4.3  Mount the active leaf slide rail 

4

4.4  Mount the door closer 

4

4.5  Shorten the connecting tube 

4

4.6  Adjust the triggering roller on the door leaf 

4

4.7  Mount the connecting tube 

4

4.8  Set the sequential locking control 

5

4.9  Check the sequential locking control 

5

4.10  Connect the EMF  

5

Start up 

5

5.1  Set the fixture point 

5

5.2  Set the release force 

5

5.3  Mount the paneling 

6

5.4  Check the EMF 

6

5.4.1 

Release EMF manually 

6

5.4.2 

Delete EMF electronically 

6

6 Operating 

6

6.1  Open and lock door 

6

6.2  Close door 

6

Dismounting, recycling and disposal 

6

WN 059385 45532 – 2017-10

dormakaba Deutschland GmbH

DORMA Platz 1

D‑58256 Ennepetal

17

0432‑CPR‑00026‑60 EN 1155: 1997/A1: 2002/AC:2006 3 8 3‑5 1 1 4

DOP_0146

dormakaba Deutschland GmbH

DORMA Platz 1

D‑58256 Ennepetal

17

0432‑CPR‑00026‑83 EN 1158: 1997/A1: 2002/AC:2006 3 8 3‑7 1 1 4

DOP_0145

Содержание GSR XEA BG

Страница 1: ...il 4 4 4 Mount the door closer 4 4 5 Shorten the connecting tube 4 4 6 Adjust the triggering roller on the door leaf 4 4 7 Mount the connecting tube 4 4 8 Set the sequential locking control 5 4 9 Check the sequential locking control 5 4 10 Connect the EMF 5 5 Start up 5 5 1 Set the fixture point 5 5 2 Set the release force 5 5 3 Mount the paneling 6 5 4 Check the EMF 6 5 4 1 Release EMF manually 6...

Страница 2: ... is authorized by dormakaba The operating of the slide rail system can be carried out by any person who is mentally and physically able 1 3 Provided documents Mounting instructions Additionally with GSR EMF XEA BG Data sheet about the use of catching devices 1 4 Symbols and abbreviations used 1 4 1 Safety instructions WARNING This statement indicates a situation of potential risk which could lead ...

Страница 3: ... for the use as fire and smoke protection closures in conjunction with the external RMZ and RM A separate verification of suitability is required for the respective fire smoke protection door 3 Product description The slide rail system ensures the correct order when closing 2 winged doors The slide rail system is intended for the mounting into the opposite hinge side The slide rail system is suita...

Страница 4: ...Insert the end caps connector into the slide rail 2 A Tighten the slide rail B Tighten the slide rail on the pre installed mounting plate C Tighten the slide rail on the pre installed lintel casing angle 4 4 Mount the door closer ATTENTION Risk of damaging the slide rail system The dimensions on the drill template of the door closer are not suitable for the mounting of this product Use the dimensi...

Страница 5: ... trigger the trigger must be moved 1 Close the fixed leaf 2 Loosen the screw 3 Push the trigger into the direction of the triggering roller 4 Tighten the screw 4 10 Connect the EMF Only for GSR EMF XEA 1 Lay the EMF connecting cables of the fixed leaf to the active leaf in a way that it is not resulting in jamming the connecting rod 2 Tighten the cable with zip ties 3 Insert the connection cable o...

Страница 6: ...ease of the RMZ etc The door leaves are released and close The active leaf closes only when the fixed leaf is closed 6 Operating Only for GSR EMF XEA 6 1 Open and lock door 1 Open door leaves to the fixture point The door leaves remain standing after letting go 6 2 Close door 1 Firstly press shut the fixed leaf then the active leaf against the resistance or press the optional manual release button...

Страница 7: ...7 GSR XEA BG GSR EMF XEA BG 2017 10 dormakaba Mounting instructions WN 059385 45532 ...

Страница 8: ...dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Germany T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com Translation of the original manual subject to change without notice ...

Отзывы: