4 Installation
The mounting of the slide rail system takes place
directly on the door lintel or optionally with a
mounting plate.
4.1 Prepare the mounting of the
slide rail
The slide rail can be mounted in 3 different options:
Option
A
= Mounting directly on the door lintel
Option
B
= Mounting with mounting plate
Option
C
= Mounting with lintel casing angle
Mounting steps for options A, B and C
1.
Prepare the power supply (24 V/48 V DC) from the
smoke detection panel to the EMF in version with
EMF.
2.
Take into account the mounting position on active
leaf G and fixed leaf S.
3.
Mark the fixing points for the closer and the slide
rails according to the hole pattern.
4.
Drill the holes.
5.
Drill the hole for the connecting cable
(24 V/48 V DC) Ø 8 mm in versions with EMF.
6.
Laying cables in versions with EMF.
Additional mounting steps for option B and C
7.
Shorten the middle mounting plate or the middle
lintel casing angle.
8.
Mount the mounting plate or lintel casing angle
onto the door profile.
4.2 Mount the sliding rail of the
fixed leaf
1.
Insert the end caps connector into the slide rail.
2. A
Tighten the slide rail.
B
Tighten the slide rail
on the pre‑installed mounting plate.
C
Tighten the slide rail
on the pre‑installed lintel casing angle.
4.3 Mount the active leaf slide rail
1.
Insert the end caps connector into the slide rail.
2. A
Tighten the slide rail.
B
Tighten the slide rail
on the pre‑installed mounting plate.
C
Tighten the slide rail
on the pre‑installed lintel casing angle.
4.4 Mount the door closer
ATTENTION
Risk of damaging the slide rail system
The dimensions on the drill template of the
door closer are not suitable for the
mounting of this product.
• Use the dimensions from the drill pictures
of the instruction of this product.
1.
Mount the door closer and lever to the door leaf
according to the enclosed instructions for the
door closer.
2.
Adjust the door closer.
4.5 Shorten the connecting tube
1.
Measure the dimension X.
2.
Shorten the connecting tube to the dimension
X‑41 mm.
4.6 Adjust the triggering roller on
the door leaf
1.
Close the fixed leaf.
2.
Close the active leaf.
3.
Unscrew the hexagon socket screw
4.
Press on the lever of the triggering roller onto the
door.
5.
Tighten the hexagon screw.
Pay attention to the torque 5 Nm.
6.
Remove the screw.
4.7 Mount the connecting tube
1.
Open of the active leaf.
2.
Open of the fixed leaf.
3.
Screw in the adjusting sleeve up to marking.
4.
Move the lever with the roll in direction to the
opened active leaf until it clicks.
5.
Insert of the connecting tube into the adjusting
sleeve of the active leaf slide rail.
6.
Insert the slide of the fixed leaf slide rail and fit
the connecting tube into the retainer.
4
GSR XEA BG/GSR-EMF XEA BG
2017-10
dormakaba Mounting instructions
WN 059385 45532
Installation