5.3  Mount the paneling

1. 

Attach the end caps.

2. 

Break off the marked gaps on the panelings. Pay 
attention that the correct side is broken off.

3. 

Mount the paneling of the glide rail.

4. 

Measure the dimension X.

5. 

Shorten the middle paneling to the dimension 
X‑30 mm.

6. 

Mount the middle paneling.

7. 

Attach the plastic shades.

5.4  Check the EMF

Only for GSR‑EMF XEA 

The EMF can be released manually or by cutting of the 
power supply.

5.4.1  Release EMF manually

1. 

Open the door leaf and lock it.

2. 

Pull on the locked door leaves.

 

‣ The door leaves are released and close. The 

active leaf closes only when the fixed leaf is 
closed. 

5.4.2  Delete EMF electronically

1. 

Open the door leaf and lock it.

2. 

Cut off power supply (i.e. operation of the manual 
release button, alarm release of the RMZ etc.).

 

‣ The door leaves are released and close. The 

active leaf closes only when the fixed leaf is 
closed. 

6  Operating

Only for GSR‑EMF XEA

6.1  Open and lock door

1. 

Open door leaves to the fixture point. 

 

‣ The door leaves remain standing after letting 

go.

6.2  Close door

1. 

Firstly, press shut the fixed leaf, then the active 
leaf against the resistance or press the optional 
manual release button.

 

‣ The door leaves are released and close. The 

active leaf closes only when the fixed leaf is 
closed.

7  Dismounting, 

recycling and 

disposal

Dismantling is the same procedure in reverse and 
must be carried out by qualified personnel. 
The product must be disposed of environmentally 
sound. Electro‑technical parts and batteries must not 
be disposed of as household waste. Dispose of 
electro‑technical parts and batteries in the arranged 
acceptance and collection points.

6

GSR XEA BG/GSR-EMF XEA BG

2017-10

dormakaba Mounting instructions

WN 059385 45532

Operating

Содержание GSR XEA BG

Страница 1: ...il 4 4 4 Mount the door closer 4 4 5 Shorten the connecting tube 4 4 6 Adjust the triggering roller on the door leaf 4 4 7 Mount the connecting tube 4 4 8 Set the sequential locking control 5 4 9 Check the sequential locking control 5 4 10 Connect the EMF 5 5 Start up 5 5 1 Set the fixture point 5 5 2 Set the release force 5 5 3 Mount the paneling 6 5 4 Check the EMF 6 5 4 1 Release EMF manually 6...

Страница 2: ... is authorized by dormakaba The operating of the slide rail system can be carried out by any person who is mentally and physically able 1 3 Provided documents Mounting instructions Additionally with GSR EMF XEA BG Data sheet about the use of catching devices 1 4 Symbols and abbreviations used 1 4 1 Safety instructions WARNING This statement indicates a situation of potential risk which could lead ...

Страница 3: ... for the use as fire and smoke protection closures in conjunction with the external RMZ and RM A separate verification of suitability is required for the respective fire smoke protection door 3 Product description The slide rail system ensures the correct order when closing 2 winged doors The slide rail system is intended for the mounting into the opposite hinge side The slide rail system is suita...

Страница 4: ...Insert the end caps connector into the slide rail 2 A Tighten the slide rail B Tighten the slide rail on the pre installed mounting plate C Tighten the slide rail on the pre installed lintel casing angle 4 4 Mount the door closer ATTENTION Risk of damaging the slide rail system The dimensions on the drill template of the door closer are not suitable for the mounting of this product Use the dimensi...

Страница 5: ... trigger the trigger must be moved 1 Close the fixed leaf 2 Loosen the screw 3 Push the trigger into the direction of the triggering roller 4 Tighten the screw 4 10 Connect the EMF Only for GSR EMF XEA 1 Lay the EMF connecting cables of the fixed leaf to the active leaf in a way that it is not resulting in jamming the connecting rod 2 Tighten the cable with zip ties 3 Insert the connection cable o...

Страница 6: ...ease of the RMZ etc The door leaves are released and close The active leaf closes only when the fixed leaf is closed 6 Operating Only for GSR EMF XEA 6 1 Open and lock door 1 Open door leaves to the fixture point The door leaves remain standing after letting go 6 2 Close door 1 Firstly press shut the fixed leaf then the active leaf against the resistance or press the optional manual release button...

Страница 7: ...7 GSR XEA BG GSR EMF XEA BG 2017 10 dormakaba Mounting instructions WN 059385 45532 ...

Страница 8: ...dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Germany T 49 2333 793 0 F 49 2333 793 4950 www dormakaba com Translation of the original manual subject to change without notice ...

Отзывы: