Installation Instructions
Chapter 8
4
115 Vac terminal block
5
Ground post
Fig. 8.5.1 115 Vac wiring example
4
5
Fig. 8.6.1 Mounting plate slots for
accessory wiring
Fig. 8.5.2 Conduit box installation
8.5 Connect customer 115 Vac to mounting plate terminal block
8.6.1
Route accessory wiring to mounting
plate.
1. Route wiring to 115 Vac terminal block
side of mounting plate (Fig. 8.5.1).
2. Accessory wiring opposite door hinge
side: route wiring into mounting plate
track (Fig. 8.6.1) to 115 Vac terminal
block side of mounting plate.
TIPS AND RECOMMENDATIONS
Accessory wiring will terminate at
ED50LE terminal board (Chapter 4).
8.6 Route accessory wiring to mounting plate
Fig. 8.5.3 PC power cord, conduit box
installation
8.5.1 Connect customer 115 Vac wiring.
WARNING
Work on electrical equipment and
115 Vac wiring installation must
be only be performed by qualified
personnel
!
WARNING
Insure disconnect supplying power
to ED50LE operator is OFF before
connecting power!
1. Route wiring to 115 Vac terminal block.
CAUTION
115 Vac wiring.
Use copper conductors only!
2. Connect 115 Vac wiring to terminal
block.
• Terminal block screw tightening torque.
CAUTION
TIGHTEN MAINS TERMINAL TO 5-7 in-lb
Use Copper Conductors ONLY
3. Connect earth ground to ground post.