This procedure is only stopped when the motor is
overloaded. The motor will switch off for 10
seconds after 10 seconds of constant operation.
On expiry of the 10-second break, the closing
action is repeated until the door closes and locks
successfully (the blocking is removed).
If the motor overloads, this error may be
acknowledged by setting the program switch to
CL
O
SE
position. This resets the waiting period in
order to enable a prompt response of the door.
The program switch has to be set to
CL
O
SE
position.
The system has now quit the Panic Closing
Function.
By setting the program switch to
CL
O
SE
position,
the control unit resumes the normal functions.
(default "door open")
The relay contact is closed when the door performs an
opening cycle, is in "open position" or performs a
closing cycle.
(default "door closed")
The relay contact is closed when the door is in the
"closed position".
(default "malfunction")
The relay contact is closed in the event of a
malfunction.
The relay contact is closed when one or both safety
beams are interrupted. The function is deactivated
when the door is closed.
The DCW address 49 is now set.
As soon as the airlock function is activated while the
door is still closed INTERNAL and EXTERNAL
ACTIVATION SENSOR signals are blocked.
An opening or closing cycle cannot be interrupted. All
airlock functions are realized via direct wiring (no bus
connection). The di erent functions may be realised
as follows:
Resetting the Panic Closing Function
4.3 Door status contacts see connection diagram
Door status contact 1 (OUT-1)
Door status contact 2 (OUT-2)
Door status contact 3 (OUT-3)
Door status contact Bell contact (OUT-4)
The system must be disconnected from
power supply while the DCW address of the
function module is set.
Setting the DCW address:
4.4 Disabling the airlock (IN 3)
DCW address 49
Set DIP switch 1 of the function module to ON position
and DIP switch 2 to
CL
O
SE
position.
Airlock function:
4.5 Door status contact 2 (OUT 2)
(Disabling of airlock if required)
4.6 Panic Closing Function (IN 4) &
Door status contact 1 (OUT 1)
4.7 Bell contact (OUT 4)
Wear parts:
We recommend to conclude a maintenance
contract with DORMA.
Cleaning:
Door 2 is disabled during the opening cycle of
door 1. (internal and external
are
deactivated.)
The locking function is disabled as soon as the door is
closed.
Door 1 is locked during the opening cycle of door 2.
e
r
a
(
deactivated.)
The locking function is disabled as soon as the door is
closed.
The relay contact is closed as soon as the door starts
an opening cycle. (Same function as function module
with ”DCW address 48”.)
Same function as function module with
“DCW address 48”.
The relay contact is closed when one or both safety
beams are interrupted. This function is deactivated
when the door is closed.
The unit must be checked and, if necessary, serviced
before it is commissioned for the
t time and
thereafter as required, but at least once a year
by a specialist engineer or by authorised specialist
personnel.
The following wear parts must be checked in regular
intervals and replaced if required in order to ensure
the smooth function of the unit.
Track rollers every 2 years
Rechargeable battery pack every 3 years
Rubber end stops at every service check
Track rail every 5 years
Toothed belt every 1,000,000 opening/closing
cycles
Floor guides at every service check
Brushes (optional)
During cleaning, the program switch must be set to
CL
O
SE
or PERMANENT OPEN in order to avoid
inadvertent movements of the door.
The entire sliding door unit (aluminium, glass, covers)
can be cleaned with a damp cloth and normal
commercial detergents. The safety beams have to be
cleaned with a dry cloth and the
r guide rails must
be cleaned.
activation sensors
internal and external activation sensors
5. Care and maintenance
·
·
·
·
·
·
·
ESA II Controller
and Wiring Manual
DORMA
6
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
DL2842-010
Lake Bluff, IL 60044
Fax: 877-423-7999
rev. A