1. Commissioning
1.1
Please note:
Work on electrical equipment may only be
performed by properly qualified electricians.
Power supply (by others) with 15 A fuse protection
must be available.
Power cord must be double-insulated, for example:
Do not use ribbon cable! The maximum cable length
of the external components must not exceed 98 ft.
1.2
Basic requirements:
·
The operator is fully assembled.
·
The protective earth is connected.
·
The safety beams are connected (optional).
·
The rechargeable battery pack (optional
is connected.
·
Components supplied separately, such as
program panel, activators, radar motion
detectors, Night-/Bank key switches and
connected.
·
The end stops are adjusted so that, at maximum
opening with, both active leaves are in contact
with the stops; and when door is closed, neither
panel touches the sealing profile.
·
The door has to run smoothly.
1.3
Commissioning
1.
Open the sliding leaves half way.
2.
Move the program switch to position
CLOSE
3.
Insure jumper is in place on the breakout or
emergency stop contacts
The door must perform a closing cycle at low
(creep) speed.
If the door performs an opening cycle, the
system must be set back to original settings.
Disconnect the power plug so that the
opening cycle stops.
Proceed on 1.5 original settings
If the door performs a closing cycle, proceed with the
learning cycle starting with the door closed.
Please note:
The safety beams and radar motion detectors are
disabled during the learning cycle, as it has to be
performed without interruptions.
In case that a fault or error should occur during this
procedure, the learning cycle will be interrupted
needs to be re-started.
1.4
Performing the learning cycle:
Press SERVICE/SELECT button until one of the
external until each one of the display
illuminates in turn.
·
The door accelerates in order to determine the
door weight.
·
The door opens at low (creep) speed to determine
the opening width.
·
The opening parameters are now stored and an
8 flashes twice on the 7-segment display.
The learning cycle is now complete.
·
The 7-segment display indicates a dot.
·
The door closes at normal speed.
Test of opening cycle
Set program switch to AUTOMATIC and push the
SERVICE/SELECT button
·
The door performs an opening cycle and is
closed after the hold-open time expires.
The following door parameters must be checked
and amended if required.
Settings: See operating instructions of adjustment.
Perform amendments with the aid of the parameterization
instructions and the 7-segment display on the control unit
or via PDA.
Menu A.:
Emergency operation (via rechargeable battery pack)
- original settings = 0
Menu r.:
Locking action depending on position of program switch
- original settings = 1
Menu L.:
Locking type original settings = 1
The locking type is not learned automatically during the learning cycle.
1.5
General information concerning the original settings.
If several settings have been changed, the door no longer
works properly, reset to original settings
·
Set program switch to
CL
O
SE
·
Open the door leaves to 50%
·
Connect power plug.
·
Press and hold the service key.
·
As soon as the power supply has been switched on,
the control unit powers up and the security checks are
performed.
An 8 is shown on the seven-segment display. When the
8 blinks twice, the original settings have been restored.
·
In case the door starts an opening cycle, press the minus
button on the control unit to change the direction of the motor.
·
Following the restoring of the original settings, differing
settings (e.g. locking type) have to be made manually either
via the buttons on the control unit or via the PDA
(parameterization) and a learning cycle has to be performed
(see 1.4)
ESA II Controller
and Wiring Manual
DORMA
3
DORMA AUTOMATICS, Inc.
924 Sherwood Drive
Toll-Free: 877-367-6211
DL2842-010
Lake Bluff, IL 60044
Fax: 877-423-7999
rev. A
E-mail: [email protected]