background image

when the driver is connected to the Doric Neuroscience Studio. These function are used through the

Channel Config-

uration

window (Fig.

4.2

).

Figure 4.2:

Light Source Channel Configuration Window

1. The

Channel Types

(Fig.

4.2

are displayed on the left side of the window. These include

Laser

light sources,

Ce:YAG

light sources and

LED

light sources, as well as the

Scope

to measure signal using the driver.

2. The

Channel Options

box (Fig.

4.2

includes

Light Source Options

and

Trigger Options

for the given channel.

a) The

Channel

(Fig.

4.2

drop-down list identifies which driver channel is currently being edited, assuming a

driver with multiple channels.

b) The

Mode

(Fig.

4.2

drop-down list includes each possible driver mode. These are used to control the pulse

sequences emitted by the light source. The options related to this mode are detailed with the

Sequence

Options

.

c) The

Current Options

(Fig.

4.2

includes the slider used to control the current sent to the light source.

• When using a

LED Driver

module, the

Overdrive

checkbox will appear. When selected, this allows the

system to exceed the normal safe current limit of the light source.

THIS SHOULD ONLY BE USED WITH

PULSED SIGNALS, AS IT CAN OTHERWISE DAMAGE THE LIGHT SOURCE.

• When using a

LEDD

, the

Low-Power

checkbox will appear. When selected, this allows reduced-power

signaling for the same voltage. This mode is only available for

CLED

modules. This allows low-power

signals to be more stable in time. The maximal current is reduced to one tenth of light source’s normal

maximal current. If the

BNC Output

is used, the voltage of the signal is proportional to the current pass-

ing through the light source, and not the voltage sent to it. For example, a driver with a normal maximum

current of 2000 mA for a 5 V signal (400 mA/V) will have a maximum current of 200 mA for a 5 V signal

(40 mA/V). The

BNC output

of the driver will still relate LED current with a 400 mA/V conversion factor.

d) The

Trigger Options

(Fig.

4.2

allow the selection of a number of trigger modes to activate a pulse sequence.

• The

Manual

trigger mode is standard, and allows direction activation by the user.

Chapter 4. Doric Neuroscience Studio

14

Содержание CLED

Страница 1: ...Connectorized LEDs LED Drivers User Manual Version 1 1 2...

Страница 2: ...tup 8 3 2 FC Connector Installation 9 3 3 Stand alone mode without Doric Neuroscience Studio Software 10 3 4 Connected to Doric Neuroscience Studio Software 12 4 Doric Neuroscience Studio 13 4 1 Light...

Страница 3: ...driver is enabled The shorting electric wire in the interlock plug can be removed and replaced by the safety interlock circuit of the laboratory This safety feature is highly recommended with UV and...

Страница 4: ...the outside of the light source The output beam exits from the Beam aperture The aperture is composed of a fiber coupling assembly that injects the emitted light into an optical fiber The standard mo...

Страница 5: ...e Studio Software allows the access to more operating modes like CW external TTL external analog internal TTL and internal Complex modes Doric Neuroscience Studio Software enables the creation of diff...

Страница 6: ...nnect the driver to an interlock system It is recom mended to connect the interlock plug to a laboratory interlock system This is critical when using LEDs in the UV or Infrared spectrum as they are in...

Страница 7: ...is a small breadboard used to hold two Connectorized LEDs this allows the light sources to be easily moved when necessary It is ordered separately from the light source Figure 2 6 LED Breadboard with...

Страница 8: ...3 Operations Guide 3 1 Connectorized LED Setup Figure 3 1 Connections to a 1 channel LED Driver in stand alone mode 1 Connect the LED Driver to the 12 VDC power supply 8...

Страница 9: ...ical fiber while the light source is ON The CLED can be operated with the driver s stand alone capabilities Section 3 3 or using the Doric Neuro science Studio software Section 3 4 3 2 FC Connector In...

Страница 10: ...The operating mode and the maximum driving current setting are independently adjusted for each channel Constant current CW Figure 3 3 Constant Current Mode Driver Signal When using the CW mode the use...

Страница 11: ...5 bottom To avoid any clipping of the output waveform the maximum current setting must be equal to or greater than the corresponding maximum analog input voltage Low power mode To enable Low power mod...

Страница 12: ...ted on Doric USB memory stick supplied with the LED driver and follow the on screen instructions 3 Connect the USB cable to the driver and the computer 4 Connect the Connectorized LED to the LED drive...

Страница 13: ...parated into two main sections Control settings and the Acquisition View Each light source driver has a number of Channels each one controlling a light source of its given type These channels accessib...

Страница 14: ...LED Driver module the Overdrive checkbox will appear When selected this allows the system to exceed the normal safe current limit of the light source THIS SHOULD ONLY BE USED WITH PULSED SIGNALS AS IT...

Страница 15: ...Current Mode Driver Signal a The Continuous Wave mode Fig 4 3 produces a continuous signal at the chosen current This mode can only be triggered manually When this mode is active the driver channel wi...

Страница 16: ...n ms for the pulse sequence For example a signal at 10 Hz frequency will output one pulse every 100 ms period whereas a pulse sequence at 0 5 Hz frequency will output one pulse every 2000 ms period ii...

Страница 17: ...ile the Smoothing option is active the Time ON is fixed at this value v The Pulses per sequence Fig 4 6 sets the number of pulses per sequence If it is set to 0 the pulse will be repeated indefinitely...

Страница 18: ...he other will adjust automatically The Time ON must be lower than 1 frequency 0 005 ms while the Duty cycle must be below 100 Figure 4 9 Internal Complex Mode Pulse Sequences viii The Types of pulses...

Страница 19: ...re 4 12 Control Settings Time Series Window The Number of series Fig 4 12 sets the number of times that the sequence will be repeated with a minimum of 1 The Time Active sets the duration of each seri...

Страница 20: ...View Light Source Channel 1 The Light Source Channel box Fig 4 13 contains all elements related to a single light source channel 2 The Scope Channel box Fig 4 14 is used to control and configure an ac...

Страница 21: ...in kilosamples per second at which mea surements are taken j The Start scope channel button activates a live measurement sequence Important measurements should not be made as a live measurement as th...

Страница 22: ...5 12 6 0 23 100 1 405 15 5 0 23 100 1 420 15 5 5 23 100 1 450 25 8 0 23 100 x1 7 465 25 7 5 23 100 x1 7 505 30 3 0 12 50 x1 6 515 40 3 0 9 5 40 x1 5 560 100 2 0 8 5 40 595 20 2 0 8 5 40 x1 2 625 20 3...

Страница 23: ...t lower current Current adjustment steps 1 mA Rise Fall time 10 s Typical Modulation minimum frequency 0 01 Hz2 Internal complex mode 0 000054 Hz Modulation maximum frequency 50 kHz 3 dB attenuation M...

Страница 24: ...commended Environmental specifications SPECIFICATION OPERATION STORAGE Use Indoor Indoor Temperature 20 C to 30 C 20 C to 60 C Humidity 40 60 RH non condensing 40 60 RH non condensing Chapter 5 Specif...

Страница 25: ...ries This means that if any single safety feature is not properly in place the light source cannot be activated The Micro controller is used to control the light source driver a Key Switch b Interlock...

Страница 26: ...to any connected light source If the Key is absent or the Interlock Plug has an open circuit it cannot receive signals from the micro controller preventing it from sending out current 6 2 Emission In...

Страница 27: ...urn instructions This warranty will not be applicable if the unit is damaged or needs to be repaired as a result of improper use or operation outside the conditions stated in this manual For more info...

Отзывы: