13
3. If you have additional sensors that need to be deleted repeat the steps until all
required sensors are deleted. If you need to program deleted sensors to a different
location, or add new sensors to the monitor's memory simply press the PROG button
twice to enter into the Programming Sensor Location mode (
see page 7
).
4. When you are finished press the PROG button to enter into the HIGH PRESSURE
program mode, which is the last item to program. If you are done with the programming
operation you can press the PROG button for 5 seconds and the monitor will return to
the normal mode of operation. This can be done in any section of the program mode
when the programming is completed.
F. High Pressure Alarm Programming
NOTE:
To exit this mode press the PROG button for 3 seconds to return to normal operation
mode.
The HIGH PRESSURE PROGRAM mode will allow you to set up your monitor to alarm if a
pressure that is 25% higher than the baseline pressure is detected. This feature can assist in the
checking of elevated heat in the tire. Pressures increase with elevated temperature. The monitor
will display HIGH, PRESSURE, and PROGRAM and the center of the screen will display
ON
or
OFF
(
see Figure 2-23 and
2-24
). To turn on or off this feature do the following:
1. Using the left and right arrow buttons you will be
able to turn this feature on and off as it is shown in
the center of the display.
2. When your selection has been made, the SET
button will need to be pressed for three seconds to
lock the selection into the memory of the monitor.
Figure 2-24
II. SETUP AND INSTALLATION
Figure 2-23
NOTE: To enter directly into this program mode you will need to
press the
button for 5 seconds until the
is displayed. Then press the
button again briefly 5 times to enter this mode (s
ee
Figure 2-23 for screen display
).
PROG
ROGRAM
PROG
P