G643 (E) Service Manual Chapter 3. Engine Mechanical System
62
High Mounted Fan Bracket Removal
Start By:
a
. Remove fan belt.
b
. Remove wires from alternator.
1
. Remove (5) Bolts from bracket.
2
. Remove the bracket assembly.
Note
: For installation of the fan bracket, reverse the
removal steps and torque mounting bolts to 50 N·m
(37 lb·ft.).
Coolant Pump Removal
Remove or Disconnect
Start By:
a
. Draining coolant from radiator.
b
. Remove by-pass hose and
c
. LP hose from pump.
d
. Remove fan belt.
1
. Remove bolts from pump pulley.
2
. Remove pulley from pump.
3
. Remove bolts from pump.