50 Hz: G625 - G690 - G750XW/XF
OPERATION & MAINTENANCE MANUAL
53
60 Hz: G655 - G750 - G800 - G850XW/XF
3.
To check the injection timing degree, ensure the
V-type edge of the flywheel housing sight hole
coincides with the engine injection timing degree
marked on the flywheel corresponding to the fuel
delivery position.
ADJUSTING INJECTION TIMING
If upper pre-checked injection timing degree is wrong,
follow the procedure below.
1.
Loosen the fixing bolts (M8) of the injection pump
driving gear in order to adjust the injection timing
slightly.
2.
Turn the crank pulley clockwise until V-groove of the
flywheel housing sight hole is aligned with the
injection timing degree of the engine.
3.
Ensure the mark on pointer provided in the injection
pump corresponds with the matching mark (FB) on
the flange surface of the drive gear by turning the
flange in the oblong holes of the drive gear.
4.
Tighten the bolt (M8) to specified torque, (2.2 kgf·m)
being careful not to move the drive gear.
5.
Once the fastening bolts are completely tightened
check the start point (injection timing degree) of fuel
delivery setting. Correct again using the above
procedure if necessary.
Engine Model
Injection Timing
(°)
DP180L
DP180LBS
21° ± 1 °
DP180LBF
19° ± 1 °
DP180LAS
21° ± 1 °
DP180LAF
19° ± 1 °
DP222L
DP222LAS
21° ± 1 °
DP222LBS
21° ± 1 °
DP222LBF
19° ± 1 °
DP222LCS
21° ± 1 °
DP222LCF
19° ± 1 °
DV2213165A_K
DV2213028A