Installation, Operation and Maintenance manual
25
PowerCore
®
Dust Collectors - Series CPV
SPECIFICATION
For other specifications on this product refer to Publication 3020.
For IPC or IPC (DR) Controller specifications, refer to Publication 2699.
For TCB specifications, refer to Publication 262-3143.
For PT Controller specifications refer to Publication 2697.
TABLE 3 – COMPRESSED AIR MANIFOLD DESIGN DETAILS
Design pressure:
6.9 bar (100 psig)
Maximum operating
pressure, PS:
6.2 bar (90 psig)
Test pressure:
10.35 bar (150 psig)
Design temperature:
-30° to +150°C
Maximum rating of pressure
relief device:
17 dm³/s at 6.9 bar (not supplied as standard)
Manifold volume:
11 litres (CPV-2 and CPV-2F)
12 litres (CPV-3, CPV-3F, CPV-6 and CPV-6F)
17 litres (CPV-4, CPV-34F, CPV-8 and CPV-8F)
27 litres (CPV-12 and CPV-12F)
Product of pressure and
capacity:
43.4 bar litres (CPV-2 and CPV-2F)
74.4 bar litres (CPV-3, CPV-3F, CPV-6 and CPV-6F)
105.4 bar litres (CPV-4, CPV-34F, CPV-8 and CPV-8F)
167.4 bar litres (CPV-12 and CPV-12F)
Material used for manifold
construction:
Structural hollow section
Minimum metal thickness
before manifold requires
special inspection:
To improve corrosion resistance the manifold is painted externally
and internally using cathodic electrocoat.
5.5 mm
1 bar = 10
5
Pa