Installation, Operation and Maintenance manual
14
PowerCore
®
Dust Collectors - Series CPV
Shut-down sequence
At the end of any period of operation it is most important that all residual
deposits are cleared from the PowerCore filter packs. To achieve this,
equipment should be shut down in the following order:
1. Stop the main fan, any blower or pneumatic conveying system, leaving the
controller and compressed air supply switched on to allow the collector to be
cleaned ‘off-line’.
To enable off-line cleaning, refer to controller manual.
2. After 10-15 minutes, switch off the controller and compressor but leave the
discharge equipment running to ensure that it is emptied.
3. After a further 5 minutes, switch off the discharge equipment if applicable.
4. Adherence to the above procedure will ensure that a PowerCore dust collector
installation is maintained at optimum efficiency.