Maintenance
Replacing Filters
The filters will need changing when the red filter condition
indicator is glowing.
A log of the changes should be maintained by the user.
The filters require attention when the LED illuminates RED
or when the extractor no longer removes fume efficiently.
It is recommended that a spare set of filters are kept on site
to avoid prolonged unit unavailability. Part numbers for
replacement filters can be found on the filters fitted in your
system.
To prevent overheating, units should not be run with a
blocked filter condition, or with dust obstruction of Inlets /
Outlets.
Pre Filter Replacement
To replace the Pre filter bag follow the procedure detailed
below.
Always use Goggles Gloves and Masks when changing the
filters.
1.
Isolate the electrical supply to the extractor
2.
Undo the 2 latches on the side of the extractor
3.
Lift the filter plate, this will allow access to the
filter, slide the filter off the plate
4.
Once removed it is recommended that the filters
are bagged and sealed
5.
Slide the new filter into place on the plate
6.
Replace the lid and secure the 2 latches
7.
Reconnect the mains supply to the unit.
HEPA Filter Replacement
To replace the HEPA filter please follow the procedure
below.
1.
Isolate the electrical supply to the extractor
2.
Undo the 2 latches on the side of the extractor
3.
Lift the filter plate, this will allow the pre filter to be
removed
4.
Unscrew the 2 knobs holding the HEPA filter cage
in place.
5.
Remove the Cage and HEPA filter.
6.
Once removed it is recommended that the filters
are bagged and sealed
7.
Fit the new filter and replace cage, secure in place.
8.
Refit the Pre filter
9.
Replace the lid and secure the 2 latches
10.
Reconnect the mains supply to the unit.