Installation
Specification DentalPRO 250
Dimensions: Height 522mm Depth 285mm Width 290mm
Weight: 8Kg
Voltage: 115/230V
Frequency: 50/60Hz
Full load current: 230V:0.9A 115V:1.2A
Power: 0.135w
Capacity:180m
3
/h
Connection to Power Supply
Please follow the above specification when selecting the
power supply outlet for the DP250, ensure the power supply
is suitable before connecting the DP250.
Check the Integrity of the electrical power cable, if the
supply cord is damaged the extraction unit should not be
connected to the mains. The supply cord should only be
replaced by a BOFA engineer as an electrical safety test may
be required after replacement.
The DentalPRO 250 unit
MUST
be connected to a properly
earthed outlet.
If your DL250 was ordered with any optional extras
please read section 4.03
before the power connection is
made as additional connections may be required before
power is connected to the extractor.
Connect the power cable to an isolated electrical supply.
The mains socket should be installed near the extractor it
should be easily accessible and able to be switched On/ Off.
The cable run should be arranged so as not to create a trip
hazard.