RP_RPH Baghouse
31
Input
102-132V/50-60Hz/1Ph
Pulse ON Time
Factory set at 100-milliseconds, or 1/10-second (not field adjustable)
Do not adjust pulse ON time unless the proper test equipment is available. Too much or too little ON time
can cause shortened filter life.
Pulse OFF Time
Factory set, the OFF time is dictated by the arm rotation speed and collector model. Refer to the table below when setting pulse
only controller (PLC only).
Open the valve to the air reservoir gauge only when verifying pulse pressure and ensure the system is in
the normal pulse operation if using a pulse only controller.
Model
Setting
66RPH, 72RP, 88RPH, 90RP
24 Spokes
132RPH, 136RP, 150RPH,
156RP, 188RPH, 200RP
48 Spokes
258RPH, 272RP
96 Spokes
Operating Temperature Range
-20° F to 180° F
Solenoid Valves
120V/60 Hz intermittent duty @ 20.9 watts
Interlocking
To ensure proper operation of the system the
main blower should not start unless the cleaning
mechanism, positive-displacement blower, and dust
removal system are all operating. It is recommeded
that an interlock device is installed between these
motors. Failure of interlocked devices should
generally not shut down the main blower, but should activate an alarm system, if available. Failure of either a rotary airlock or
screw conveyor with separate drives should shut down all other drives and alarm the operator. This will avoid filling the collector
with dust.
filter centerlines fall on radial
lines called spokes