BIOCLASS iC 150
25
ALARM CODES
The
BIOCLASS iC 150
boiler is equipped with an electronic control that performs continuous self-testing
to detect any boiler malfunctioning. When the electronic control detects a functioning error, this is
indicated by an alarm code on the display. The following list includes the possible alarm codes:
code ALARM
DESCRIPTION
E-01
Open circuit
S
c
boiler sensor.
The boiler sensor is damaged or disconnected. Please
contact your nearest official Technical Assistance
Service to have it replaced.
E-02
Closed circuit S
S
c
boiler sensor.
E-03
Open circuit
S
col
upper sensor of the tank or
needle.
The upper sensor S
col
is broken or disconnected.
Please contact your nearest official Technical
Assistance Service to have it replaced.
E-04
Short circuit
S
col
upper sensor of the tank or
needle.
E-05
Overheating of fuel inlet,
Te
.
The fuel inlet pipe has exceeded the safety
temperature of 80ºC and will lock-out boiler
functioning. To unlock the boiler operation, once the
temperature has dropped, press the button on the
safety thermostat and restore operation by pressing
the RESET button on the control panel.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-06
Failure on start up.
Check the fuel content in the reserve tank.
Calibrate the feed auger.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-07
Error in "Ash cleaning" start phase.
These alarms are triggered whenever a malfunction is
detected in the ash cleaning system of the burner.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-08
Error in "Ash cleaning" final phase.
E-09
Limit switch error
FCp1 or FCp2
"Ash
cleaning".
E-10
Boiler overheating.
The water in the boiler has exceeded the safety
temperature of 95ºC and has locked-out its
functioning. The boiler will unlock automatically when
the boiler temperature drops to 90ºC.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-11
Safety thermostat, Ts
The boiler has exceeded the safety temperature of
100ºC. The boiler will cut out. To unlock it, press the
safety thermostat button when the temperature has
dropped.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-12
Burner pellet level sensor enabled
The pellet level sensor of the burner has detected that
the inlet pipe is full of pellets. The boiler will unlock
automatically when the pipe is emptied.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-13
Insufficient air depression.
Check the correct operation and connection of the air
pressure sensor and that the burner and ash drawer
are correctly placed in the boiler.
If this alarm occurs repeatedly, please contact the
nearest official Technical Assistance Service.
E-14
Fall in air depression.
E-15
Insufficient air depression in pre-flushing.
Содержание BIOCLASS iC 150
Страница 1: ...BIOCLASS iC 150 Biomass boiler EN INSTALLATION AND OPERATING INSTRUCTIONS ...
Страница 2: ......
Страница 15: ...15 BIOCLASS iC 150 ...
Страница 64: ...EN 64 BIOCLASS iC 150 23 CONNECTIONS DIAGRAM 23 1 Boiler ...
Страница 68: ...EN 68 BIOCLASS iC 150 ...
Страница 77: ...77 BIOCLASS iC 150 NOTES ...
Страница 78: ...EN 78 BIOCLASS iC 150 NOTES ...
Страница 79: ...79 BIOCLASS iC 150 NOTES ...