39
BIOCLASS iC 150
12
TECHNICAL MENU
The
"Technical Menu"
consists of a series of boiler operating settings that may be modified, although this
must be done by a person with sufficient technical knowledge of the meaning of each setting or by
sufficiently qualified staff. Any inappropriate adjustment of any parameter of the
“Technical Menu”
may
cause a serious malfunction of the boiler and may cause damage to people, animals and objects.
To access the
“Technical Menu”
press the MENU and RESET symbols simultaneously for 5 seconds.
The request for an access code “cod” will appear on the screen
(see “Entering the code”)
. Once the correct
access code has been entered, using the symbols “
+
” or “
-
” for Heating
(20)
will browse through the
menu parameters (
P.01
.
P.28
). Once the desired parameter is selected, by pressing the
symbol we
can access it and adjust or modify it. Once the desired parameter has been adjusted, press
again to
save and return to the
“Technical Menu"
. In the
“Technical Menu”
or within any parameter of it, press
RESET to return to the previous display level without saving. These parameters are listed in the table
below and are described in detail in the following sections of the manual:
No.
Parameter
Display
Code
Access code
(default value 1234)
P.01
Boiler model
P.02
Minimum boiler power adjustment
P.03
Maximum boiler power adjustment
P.04
General fan factor
(
This is only shown with the automatic fan
adjustment switched off
)
P.05
Fuel for ignition
P.06
Fuel.
(
This is only shown with the lambda combustion
control switched off
).
Содержание BIOCLASS iC 150
Страница 1: ...BIOCLASS iC 150 Biomass boiler EN INSTALLATION AND OPERATING INSTRUCTIONS ...
Страница 2: ......
Страница 15: ...15 BIOCLASS iC 150 ...
Страница 64: ...EN 64 BIOCLASS iC 150 23 CONNECTIONS DIAGRAM 23 1 Boiler ...
Страница 68: ...EN 68 BIOCLASS iC 150 ...
Страница 77: ...77 BIOCLASS iC 150 NOTES ...
Страница 78: ...EN 78 BIOCLASS iC 150 NOTES ...
Страница 79: ...79 BIOCLASS iC 150 NOTES ...