Before starting the machine after a gas conversion, a leak test must be carried out: To carry out the
test, open the gas to the device with the device
OFF
and use a specific spray type bubble detector to
propane gas or a specific leak detector for propane gas. All points and connections within the machine
and also at the connection must be carefully checked.
-
When the machine has been modified to work with a type of gas other than Specified on the
nameplate, it will be necessary to place the three labels that correspond to: the new technical
data, who is responsible for the conversion and that the control has been updated correctly.
The labels are inside the plastic bag of the new injectors
.
Place all three labels, properly filled in if applicable at the following locations.
25, 30, 35 and 50 Lb
The labels to be placed are those indicated on the plan as numbers 17, 18 and 19
65/80 Lb
21