25 / 30 / 35 / 50 Lb
65 / 80 Lb
STANDARD & RECIRC.
STANDARD & RECIRC.
Voltage and Standard Wiring
V
120V 1N
120V 1N
Frequency
Hz
60
60
Cable Section 120V 1N+G / Fuse
Nº x AWG / A
3 x 12 / 20
3 x 8 /
20
Input terminals, electrical mains connection.
3.5. Connection to gas (only gas models)
All gas models are prepared to work with propane gas (LPG) or natural gas and with a burner pressure
and a gas according to the one on the nameplate. Check that the type of gas and the pressure value in
the burner correspond to the rating plate. If not, you should consult with the provider.
The dryer has spare injectors and a new rating plate in case it is necessary to install the appliance to
operate with a different gas group, allowing installing the machine in many countries with the main
fuels.
In the tables on the following page you can check, for each type of gas and in different countries, the
diameter of the injector and the burner pressure suitable to operate correctly.
A listed connector in compliance with the Standard for Connectors for Gas Appliances,
ANSI Z21.24 • CSA 6.10, shall be used to connect the dryer to the supply piping.
MACHINE
MAINS
17