Door
All
models will be delivered with right hand door hinging, but it is possible for
the customer to change the door hinging from right to left hand.
Replacement
of
door
panel is possible without removing the door. Only the side
profile of the door frame has to be removed.
Equipment
All models incorporate a thermo-electric flame failure safety device and a piezo
lighting system.
The equipment for electric and gas operation is located at the rear of the cabinet
and manipulated from inside the cabinet.
The gas shut-off valve and the electric voltage-change switch are interlocked so
that both methods of operation cannot be inadvertently used at the same time.
The electric and gas thermostats are of the Ranco-make.
Version
All models will be available with combination equipments for LP gas and 110 volts
A.C. or LP gas/110 volts A.C. and 12 volts D.C.
2.
INSTALLATION INSTRUCTIONS
For LP-gas and electric operation in Motor Homes and Recreational Vehicles.
General instructions
The refrigerators outlined herein have been design certified under ANS 221.19
Refrigerators by the American Gas Association for installation in a mobile home or
recreational vehicle and are approved by the Canadian Gas Association.
The certifications are, however, contingent on the installation being made in
accordance with the following instructions,
The installation must conform with:
In U.S.A.:
1.
2 .
3.
4.
In
1.
2 .
Installation of Gas Appliance and Gas Piping, 221.30 - 1964.
Mobile Homes
A
119.1 - 1969.
Recreational Vehicles A 119.2 - 1970. The unit must be electrically grounded in
accordance with the National Electrical Code ANSI CI - 1968, when installed if
an external alternating current electrical source is utilized.
Any applicable local code,
Canada:
C S A Standard B 149. “Installation Code for Gas Burning Appliances and Equipment”
C S
A
Standard B 210.1/Z 240.4. “Gas equipped recreational vehicles and mobile
homes”