background image

17.

THERMOELECTRIC 

 FAILURE SAFETY DEVICE (see fig, 58)

All

A l l

models equipped with an automatic failure device.

S

Fig. 58

gas operated or combined gas/electric refrigerator models dealt with in this

service instruction are equipped with an automatic failure device.

 purpose of incorporating an automatic flame failure device in the burner assem-

bly is to prevent unburned gas to escape from the burner and to avoid a fire hazard,

if, for some reason or other, the flame has been extinguished or blown out,

The safety device consists of the following parts:

1.

2.

3.

6.

7.

8.

9.

Spring loaded push button

Gas valve

Housing

Sensing clement with the hot junction of the

thermocoup   (Feeler)

Enamel insulated copper thread

Electromagnet

Outer tube

Armature

Spring

The 

 safety device functions as follows:

By pressing the push button (1) the gas valve (2) is opened and the gas can pass 

housing (3) on to the 

At the burner the feeler (4) is located. When the gas

flame of the burner is lit, some heat is transferred to the feeler 

 The hot

junction of the thermocouple is thus heated and an electric current is g e n e r a t e d .

This current passes through the copper wire (5) to the electromagnet (6) and back

through the outer tube (7). As soon as the electric current is generated, the

electromagnet attracts the armature (8) with the valve 

 The push button can 

be released,

As long as current is flowing, the 

 

 kept open and allows gas to pass co 

burner.

When the flame is extinguished, the heat transfer to the hot junction is 
and no electric current is generated.

 armature (8) with the valve (2) is 

forced back by the spring (9) and the gas flow through the valve (2) is  c l o s e d .

Important: 

 lighting the burner the push button (1) should be pressed f 

 

held in that position about 10 seconds, otherwise the gas may not get 

the burner properly,

Содержание RM24A

Страница 1: ...441 Bonelli St City of Industry CA 91746 81 8 968 9431 Canada DOMETIC DISTRIBUTION INC 866 Langs Drive CambrIdge Ontario N3H 2N7 Canada 51 9 65 3 439 0 Edition1 Publication No 4528 E Service May 1973...

Страница 2: ...ing unit 22 Cooling unit replacemen t 23 GAS ELECTRIC EQUIPMENT Gas equipment for RM24 28 Dual electri c equipment for RM24 29 Car electric equ ipment for RM36C RM46 RM47 RM66 RM67 RM76 RM77 _ _ _ _ 3...

Страница 3: ...ed in place with the door pan and magnetic gasket Equipment Fool proof electric gas interlock system Thermo electric flame failure device Flint lighting system The electric and the gas thermostats are...

Страница 4: ...12 volts D C 2 INSTALLATION INSTRUCTIONS For LP gas and electric operation in Motor Homes and Recreational Vehicles General instructions The refrigerators outlined herein have been design certified un...

Страница 5: ...ck up wrench to prevent undue rotation of the gas cock For hook up and servicing purpose the lower vent is constructed as a lift out panel The gas supply system must incorporate a pressure regulator t...

Страница 6: ...iding valuer calculated in consideration of 0 5 V voltage drop about 7 input loss in the connection cables without taking into account the losses at the terminals Maximum length of two conductor cable...

Страница 7: ...already fitted on the front frame of the refriger ator r Be careful not to damage the sealing strip applied to the bottom of the enclosure when the refrigerator is put in place Any space between the...

Страница 8: ...torage compartment Clearance B from rear of condenser Clearance C on top of condenser Refrigerator model 1 RM66 RM76 RM67 RM77 See minimum ventilation height figures Kit No 1 RM24 comprising Upper sid...

Страница 9: ...vent Dometic V 2019 Lover side vent Dometic RM2217 see Fig 6 Dimensions pertaining to the installation are shown under measurements VENTING MEANS Fig 1 Roof vent for Kit No 3 Dometic V 2019 c Cutout s...

Страница 10: ...et Refrigerator Overall dimen models A B Depth Width RM24 478 486 RM36C 556 513 RM46 RM47 631 547 RM66 RM67 631 547 RM76 RM77 625 595 ions C Height 562 720 785 985 1435 e Cabinet overall dimensions C...

Страница 11: ...e refrigerator are and will year remain absolutely gas tight Check at least twice a of kinks and sharp ends The gas line should be free After installation the gas checked for leaks up to the periodica...

Страница 12: ...ble fig 13 3 Pull the driving disc A outwards fig 14 3 WI Fig 13 Fig 14 4 Turn the lever C of the gas cock into vertical position D see fig 15 3 Release the driving disc which is then pulled inwards b...

Страница 13: ...lation round the unit s parts behind the cabinet is unrestricted Good refrigeration performance is dependent upon adequate ventilation of the refrigeration unit 3 UNUSED OR ABANDONED REFRIGERATORS An...

Страница 14: ...l gently so that the free side of the panel can be slipped into corresponding groove of the door frame 5 Push the panel downwards so that the lower horizontal edge of the panel is fitted in the bottom...

Страница 15: ...d in a set consisting of the gasket and of necessary fastening strips and screws and is ordered under part No 290 07 33 00 3 The replacement is made as follows 1 Remove the door and place it with its...

Страница 16: ...revent scratches and dents 4 The screws holding the door pan in place are hidden by the door gasket Pull the door gasket to one side and remove all screws A see fig 24 from the door plate 6 REPLACEMEN...

Страница 17: ...the carrier A inwards by means of a blunt mandrel or pin fig 27 and remove the shutter Pry the spring housings B fig 27 away from the lining so that it snaps out and turn the spring housings downwards...

Страница 18: ...e screwdriver is applied in front of one of the plastic tongues B fig 29 which hold the inner panel and the shutter front together 5 Replace the sealing gasket round the inner panel and snap the inner...

Страница 19: ...latch should face the cabinet opening 4 Refit the door and the upper hinge bolt CAUTION Check that the door closes easily and that the door gasket seals well on all sides If necessary adjust by reset...

Страница 20: ...ervicing an absorption system refrigerator piping do not puncture or break the Should a break occur and ammonia contact the skin wash the affected area immediately with clear vater vessel Do not attem...

Страница 21: ...ng device WATER SEPERATOR Fig 36 Cooling Unit 351A gas electric operation for model RM67 with defrosting device Cooling Unit 352A gas electric operation for model RM66 without defrosting device Coolin...

Страница 22: ...uid balance to the unit The temperatures on various parts of a unit vary continuously when it is operating on thermostatic control and it is impossible to base a judgment on the symptoms given unless...

Страница 23: ...lease the capillary clamp by removing the plastic rivet B and straighten the thermostat capillary tubes Remove the plastic cover C by means of pulling it towards the right hand side which will release...

Страница 24: ...e height Remove the thermostat capillary tubes by loosening the two screws A on the evaporator fins Fig 41 and fig 42 CAUTION The locations of the thermostat capillary tubes should be noted at this ti...

Страница 25: ...evaporator flange otherwise improper cabinet performance may result Remove the connection block cover on the side of the boiler case and disconnect the two electrical wires where they join the heater...

Страница 26: ...y loosening the two screws B on the evaporator fins fig 47 CAUTION The locations of the thermostat capillary tubes should be noted at this time for relocation later on The tubes must be replaced in th...

Страница 27: ...w on the burner housing and remove the burner housing from the boiler case Carefully slide absorption unit straight out of the cabinet CAUTION Be careful not to damage the inner liner and the location...

Страница 28: ...with nipple nut 11 Thermostat Ranco V35 12 By pass screw 13 Thermos tat knob 14 Screw 15 Indicator 16 Thermo coup le 17 Lock nut 18 Washer 19 Distance tube 20 Distance nut 21 22 23 24 25 26 27 28 29 3...

Страница 29: ...ock with bracket 28 Screw 29 Protection tube 30 Thermostat Ranco A50 31 Nut 32 Thermostat cover 33 Screw 34 Plastic rivet 35 Capillary clamp 36 Grommet 37 Screw 38 Clip 39 Switch knob with dial 12 DUA...

Страница 30: ...ary tube for gas thermostat 15 Shut off valve 16 Push button for lighter 17 Piezo lighter 18 Lighter electrode 19 Knob for releasing safety device 20 Knob for gas thermostat 21 Fuel selector LP gas l1...

Страница 31: ...31 3 27 _ il ___ ____ 2 i Fig 51...

Страница 32: ...ss flame it will be necessary to clean the thermostat valve and valve seat Note The thermostat will not close to by gass on setting O at least S C 40 F unless the thermostat bulb is cooled down to Pro...

Страница 33: ...let placed l 3 into flame 15 THE GAS BURNER see fig 55 The burner has the jet horizontally located and the burner mixing tube is formed as a bend with vertical outlet The pri mary air inlets are pre s...

Страница 34: ...Xodel BM24 RM36C BM46 RM47 BM66 BM67 R 76 RM77 Baffle Width x Length nun inches 10 x 100 3 a x 4 20 x 100 3 4 x 4 20 x 100 314 x 4 20 x 100 3J4 x 4 20 x 150 314 x 6 75 3 75 3 75 3 75 3 75 3 Part Jo B...

Страница 35: ...button 1 the gas valve 2 is opened and the gas can pass c e housing 3 on to the burr r At the burner the feeler 4 is located When the gas flame of the burner is lit some heat is transferred to the fee...

Страница 36: ...the feeler is located as in figure 7 Check that no burrs are inside valve housing B which nay cause leaks Screw plug A onto the valve housing B taking care not to damage the threaded hole in the alum...

Страница 37: ...from the cord and iemove the heater Make sure the new heater is fully inserted before bending back the wire clip with caution or it might snap off Reset the electric connections Be careful to put the...

Страница 38: ...k I I I I Brown I Rrd P 4 I 110 Volts I Heating element Terminal block Switch Fig 64 1lOV for RM36C RM46 RM47 RM66 RM67 RM76 RM77 Heater Thermostat Fig 6 5 l2V llOV for RM36C RM46 RM47 RM66 RM67 Term...

Страница 39: ...ows If the gauge is filled with water to zero and the lower column is 5 5 inches 140 mm below zero the other column will also be 5 5 inches 140 IX By adding the tvo together 5 5 5 5 11 inches 280 mm w...

Страница 40: ...nnot be inadvertently used at the same time 23 GAS OPERATION See Fig 70 and 71 1 Ensure that the voltage change switch A is at the OFF position 2 Turn the gas valve C so that the handle is in line wit...

Страница 41: ...of the flame failure safety device and after 5 10 seconds press the button E to the piezo lighter The pressing may have to be repeated Through the reflector F it can be observed that the burner is li...

Страница 42: ...of the vehicle so that the bubble is in the center ring of the level Fig 7 7 When the vehicle is on tow the continuous rolling and pitching movement vi11 not affect the refrigerator as long as the mov...

Страница 43: ...the lining with lukewarm water to which a little baking soda may be added Dry thoroughly especially around door frames and door gasket Warm water only should be used to wash the cooling evaporator ice...

Страница 44: ...Xake sure that all gas appliances are closed Test gas connections and all joints in the gas line with soap and water solution up to and including gas cock Never look for a leak with an open flame Use...

Страница 45: ...against the serrated wheel Replacement of the serrated vheel RM24 If after several years of use the lighter does not function properly even with a new flint the serrated vheel might be worn out and n...

Страница 46: ...stening the electrode on the burner housing make sure that the insulation plate is properly fitted between the burner housing and the electrode see fig 78 Replacement of Piezo lighter complete 1 Relea...

Страница 47: ...of appropriate voltage type see table page 37 8 Intermittent electricity supply Look for loose connections or other reason for interruption and correct h Drop in supply voltage The supply voltage sho...

Страница 48: ...rt in valve of the thermostat Remedy Remove any restriction See par 28 Fit new bottle Adjust position of feeler point in flame See par 15 Clean by pass screw with alcohol and by blowing through with a...

Страница 49: ...tion in voltage supply No loose electric connections Thermostat intact 16 No unit leaks 17 Safety valve intact 45 PACKING OF DEFECTIVE UNITS Particular attention must be paid to the packing of a repla...

Страница 50: ...ion CJ that several causes can be responsible for 22 2 s 2 the one effect The real cause or causes u r 8 u G 4 o should bc determined by a process of elipi u 24 2 J b See paragraph No nation investiga...

Страница 51: ...ce clogged The thermocouple tip not in position No contact between thenwcouple and safety valve mamet Faulty safety valve magnet Improper maxisum flame By pass flame too small I 48 Gauze in burner hea...

Страница 52: ...same time check the flue baffle that it is clean and free from soot Heavy soot formation indicates improper functioning of the burner Clean baffle and flue Further clean cooling unit and floor under r...