Fastening and connecting the inverter
PerfectPower
14
!
Earthing the inverter
➤
Connect the earth connection on the inverter (fig.
2
4, page 3) with the earth of
the vehicle.
Connecting the inverter to the battery
I
A
➤
Connect the terminal on the red battery connection cable to the positive terminal
(fig.
2
7, page 3) on the inverter.
➤
Connect the terminal on the black battery connection cable to the negative
terminal (fig.
2
6, page 3) on the inverter.
➤
Check the connections are secure.
You might have to tighten the screws again later.
I
➤
Connect the red battery connection cable to the positive terminal on the battery.
➤
Connect the black battery connection cable to the negative terminal on the
battery.
WARNING! Danger of electrocution!
If you wish to connect more than one consumer to the inverter and install
a socket distributor loop, you must arrange a circuit breaker (residual
current circuit breaker) and set a grounding bridge in the inverter, see
chapter “Connecting multiple consumers” on page 15.
NOTE
Please be aware that all volatile memories of the connected electric con-
sumers will lose their stored data if the battery is disconnected.
NOTICE!
Make sure the polarity is correct. If the positive and negative
connections are reversed, this may damage the device.
NOTE
Sparks may be produced when the connections are made due to the
internal capacitors being charged.