![Dometic PP 1002 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/dometic/pp-1002/pp-1002_installation-and-operating-manual_2518733017.webp)
EN
PerfectPower
Using the inverter
17
9
Using the inverter
A
A
When using the inverter, observe the following instructions:
•
If the battery voltage drops below the alarm value during operation (see “Low
voltage alarm” in chapter “Technical data” on page 21), a warning signal sounds
and LED “UVP” (fig.
1
7, page 3) lights up.
•
If the battery voltage drops below the shutdown value (See “Low voltage
shutdown” in chapter “Technical data” on page 21), the inverter switches off.
•
If the inverter overheats, it switches off and LED “OLP” (fig.
1
6, page 3) lights
up.
After it cools down, the inverter automatically switches back on.
•
When operating the inverter at a high load for lengthy periods, it is advisable to
start the engine in order to recharge the vehicle battery.
➤
Connect your consumer to the 230 V output (fig.
1
4, page 3).
You can also connect a socket distribution system.
9.1
Using the inverter without remote control
➤
Set the main switch (fig.
2
1, page 3) to
–
“ON” to switch the inverter on
–
“OFF” to switch the inverter off
✓
LED “POWER” lights up when the inverter is switched on.
NOTICE!
If no circuit breaker is present:
If the inverter is connected to the
external mains voltage, the 230 V output socket is earthed.
If there is no external mains voltage, the inverter is only connected to the
battery (DC operation). In this case, the 230 V output socket is not
earthed, but safeguarded with the protective insulation instead.
NOTICE! Risk of short circuit!
You must switch on the inverter first before switching on the consumers.