
MANUAL REFRIGERATOR
DIAGNOSTIC FLOW CHART
NO OPERATION
A.
1
Check Supply Voltage
1. 110 Volt Plug
2. Wire Size
C o r r e c t a s N e c e s s a r y
OK
B.
V
Check Fuse
Correct as Necessary
NOT OK
Replace if Defective
OK
.c.
Check wiring
Correct as Necessary
NOT OK
OK
D.
Check Switch
NOT OK
Correct as Necessary
(Page D-6-20, Para. 66)
OK
E.
V
Check Thermostat
, Correct as Necessary
NOT OK
Continuity Check
D-4-l
Manual
Compliments
of
Northwest
RV
Supply
Printed
From
http://www.nwrvsupply.com