![Dometic ASCDU15HV 1161 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dometic/ascdu15hv-1161/ascdu15hv-1161_installation-and-operation-manual_2518185009.webp)
9
EN
Universal Air Conditioning Unit
Specifications
4 .4 Q3 Control Dimensions
OFF
AUTO
COOL
HEAT
AUTO
MODE
DEHUMIDIFY
(Side)
q
e
w
r
6
Q3 Control Dimensions
Ref .
Dimension
1
2.51 in. (64 mm)
2
3.97 in. (101 mm)
3
0.75 in (19 mm)
4
0.25 in. (7 mm)
A
B
B
7
Cut Out Dimensions
Dimension
Size
A
1 in. (25 mm) Hole in Bulkhead
(for CXP Cable Connection)
B
0.1 in. (2 mm) Mounting Holes
I
The Q3 Control package includes the drill and cut
template (P/N 086812).
4 .5 Cable Lengths
Description
Size
Display Cable
15 ft (5 m) Typical
Indoor Air Sensor
15 ft (5 m) Standard on
Self-Contained Systems
Outside Air Sensor (optional) 75 ft (23 m) Maximum
Custom Display-Cable
[All Lengths are Supplied
in Standard 5 ft (1.5 m)
Increments]
75 ft (23 m) Maximum
I
The maximum length of display and sensor cables
is 75 ft (23 m).
4 .6 System Inputs
The following system features are monitored via the Q3
control:
• Ambient or inside air-temperature
• High refrigerant pressure
• Low refrigerant pressure
• Optional outside air-temperature sensor