AZ motor
Edition 4
Instructions for bearings replacement
17
4.
SERVICING OF THE MOTOR FOR BEARINGS
REPLACEMENT
Replacement of the motor bearings is an example of service
intervention.
Any service intervention should be performed by a qualified
person.
Disturbing noise from fan motor!
Check by spinning the wheel by hand and listen for noise from the bearings.
Establish the replacement of bearings if noise from bearings is detected.
RISK OF ELECTRIC SHOCK.
Before service intervention, ensure that motor controller is
disconnected by the mains voltage and that motor does not rotate.
The fan, mounted on the motor shaft, could rotate due to influence
of the overpressure in the air channel or wind. The rotation of the
fan causes the rotation of the motor. In such case the motor
generates electrical voltage. And a touch of the non-insulated wires
of the connection cable can lead to serious injuries.
RISK OF INJURY BECAUSE OF FLYING OBJECTS.
During the service intervention protecting glasses and protective
gloves should be used.
Содержание AZ 108
Страница 1: ...AZ MOTOR INSTRUCTIONS FOR BEARINGS REPLACEMENT Edition 4 June 2014 ...
Страница 13: ...AZ motor Edition 4 Instructions for bearings replacement 13 2 3 2 Parts of motors AZ 108 AZ 150 AZ 220 ...
Страница 14: ...AZ motor Edition 4 Instructions for bearings replacement 14 Picture 4 Main motor parts AZ 108 AZ 150 AZ 220 ...