Installing an external reader and connecting it to Access Manager
(control unit)
81
This reader is connected to the ENiQ Module Reader/Module Reader Terminal
via the following terminals:
External reader
Control unit (ACM/ACM-T)
Terminal 7 / +Ub
Terminal 7 / 12–24 V
Terminal 6 / GND
Terminal 8 / GND
Terminal 3 / Data “A”
Terminal 19 / RxD / A
Terminal 4 / Data “B”
Terminal 18 / TxD / B
Installation
Screw the connected return
module onto a standard 55 flush-
mounted socket following
completion of electrical wiring
using the supplied screws.
Align the return module
horizontally.
Place the connected return
module on a 55 switch box.
The arrow of the top marking on the
return module must point upwards.
Align the return module
horizontally.
Attach the return module to the
switch box with the screws
included in the scope of supply
Insert the front module into the
standard intermediate frame free
of tension.
It may be necessary to rework the
standard intermediate frame in the
corners for this purpose.
When dismantling the front
module, make sure the sabotage
contact is not damaged.