Assembling the device
48
Following connection to the passive reader, connect the Access Manager or
Access Manager Terminal to the network. Follow the instructions from page
48 for this purpose.
Connecting the Access Manager or RF Net Manager to the network
ATTENTION!
Property damage through incorrect connection.
Only carry out the network connection.
Do not connect the voltage supply via PoE (Power over
Ethernet) yet.
Make sure that the cable pairs for Ethernet RD and TD remain twisted up to
the terminal on the DOM device.
Data is generally transferred at terminals 11 to 14.
If a PoE "End-Span Device" (PoE switch) is used, both data transfer and
energy supply is carried out on the data lines at terminals 1 to 4 (wires 1, 2, 3,
6). However, you can still connect wires 4, 5, 7 and 8 to terminals 5 and 6 for
insulation if they are not used for any other purpose in your network wiring.